Flicker cone electroretinogram in dichromats and trichromats
To measure cone signal strengths in the flicker electroretinogram (ERG) of dichromats and trichromats, we developed a set of flickering stimuli (30 Hz), which excite the middle-wavelength-sensitive (M-) and long-wavelength-sensitive (L-) cones independently. ERG responses to eight different ratios o...
Gespeichert in:
Veröffentlicht in: | Vision research (Oxford) 1998-11, Vol.38 (21), p.3391-3396 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To measure cone signal strengths in the flicker electroretinogram (ERG) of dichromats and trichromats, we developed a set of flickering stimuli (30 Hz), which excite the middle-wavelength-sensitive (M-) and long-wavelength-sensitive (L-) cones independently. ERG responses to eight different ratios of L- to M-cone contrasts were recorded from each subject. The short-wavelength-sensitive (S-) cone contrast was 0% in all measurements. The recordings were Fourier analyzed to determine the amplitude of the fundamental component. ERG threshold values for each subject resulted in ellipses when plotted in an L-/M-cone contrast space. As expected, the orientations of the threshold ellipses of the protanopes (
N=2) were parallel to the L-cone axis, whereas those of the deuteranopes (
N=2) were parallel to the M-cone axis. For the trichromats (
N=5), there was considerable interindividual variation in ellipse orientation. |
---|---|
ISSN: | 0042-6989 1878-5646 |
DOI: | 10.1016/S0042-6989(97)00466-5 |