Development and validation of an improved enzyme-linked immunosorbent assay for the detection of thyroglobulin autoantibodies in canine serum samples

An enzyme-linked immunosorbent assay to detect thyroglobulin autoantibodies (TGAB) in canine serum was developed and validated. The test result for each sample was derived from the optical density readings (OD) and expressed as an Ab-score(%) calculated from three in-house calibrators. The assay spe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Domestic animal endocrinology 1998-11, Vol.15 (6), p.525-536
Hauptverfasser: Iversen, L, Jensen, A.L, Høier, R, Skydsgaard, M, Kristensen, F
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An enzyme-linked immunosorbent assay to detect thyroglobulin autoantibodies (TGAB) in canine serum was developed and validated. The test result for each sample was derived from the optical density readings (OD) and expressed as an Ab-score(%) calculated from three in-house calibrators. The assay specifically detected TGAB as judged from lack of response in the assay after samples had been incubated with specific antigen. Intra- and interassay coefficients of variation ranged from 2.0–4.9% and 4.6–9.9%, respectively. The detection limit, an Ab-score of 5.6%, was close to the median Ab-score of 10% observed in healthy dogs ( n = 132). The median Ab-score of dogs with primary hypothyroidism and lymphocytic thyroiditis ( n = 11), skin diseases ( n = 35), and non-thyroidal diseases ( n = 63) was 340%, 12%, and 8%, respectively. The prevalence of TGAB in hypothyroid dogs with lymphocytic thyroiditis (sensitivity) was 91% (95% confidence limits: 59%–99%). In dogs with dermatological diseases without lymphocytic thyroiditis the prevalence of TGAB was 3% corresponding to a specificity of 97% (95% confidence limit: 85%–100%). In dogs with non-thyroidal diseases and healthy dogs the prevalence of TGAB was 5% and 6%, respectively. The diagnostic accuracy of serum TGAB was evaluated by subjecting the data from 11 dogs with lymphocytic thyroiditis and 35 control dogs without lymphocytic thyroiditis to receiver-operating characteristic curve analysis. The area under the receiver-operating characteristic curve (W = 0.966; 95% confidence limit 87%–100%) was significantly higher than that of a worthless test (0.5) (P < 0.0001), thereby indicating that serum TGAB measurements distinguished between dogs with and without lymphocytic thyroiditis.
ISSN:0739-7240
1879-0054
DOI:10.1016/S0739-7240(98)00040-X