Serial volumetric (three-dimensional) intravascular ultrasound analysis of restenosis after directional coronary atherectomy
Objectives. We report the use of three-dimensional (volumetric) intravascular ultrasound (IVUS) analysis to assess serial changes after directional coronary atherectomy (DCA). Background. Recent serial planar IVUS studies have described a decrease in external elastic membrane (EEM) area following ca...
Gespeichert in:
Veröffentlicht in: | Journal of the American College of Cardiology 1998-12, Vol.32 (7), p.1874-1880 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objectives. We report the use of three-dimensional (volumetric) intravascular ultrasound (IVUS) analysis to assess serial changes after directional coronary atherectomy (DCA).
Background. Recent serial planar IVUS studies have described a decrease in external elastic membrane (EEM) area following catheter-based intervention as an important mechanism of late lumen renarrowing.
Methods. Thirty-one patients with de novo native coronary lesions treated with DCA in the Serial Ultrasound Restenosis (SURE) Trial and in Optimal Atherectomy Restenosis Study (OARS) were enrolled in this study. Serial IVUS was performed before and after intervention and at 6 months’ follow-up. In a subgroup of 18 patients from the SURE trial, IVUS was also performed at 24 h and at 1 month postintervention. Segments, 20-mm-long (200 image slices), were analyzed using a previously validated three-dimensional, computerized, automated edge-detection algorithm. The EEM, lumen, and plaque+media (P+M = EEM−lumen) volumes were calculated.
Results. At follow-up, lumen volume was smaller than at postintervention (159 ± 69 mm3vs. 179 ± 49 mm3, p = 0.0003). From postintervention to follow-up, there was a decrease in EEM volume (377 ± 107 to 352 ± 125 mm3, p < 0.0001), but no change in P+M volume (p = 0.52). The Δ lumen volume correlated strongly with ΔEEM volume (r = 0.842, p < 0.0001), but not with ΔP+M volume. In the 18 patients from the SURE Trial, the decrease in lumen and EEM volumes occurred late, between 1 month and 6 months of follow-up.
Conclusions. Volumetric IVUS analysis demonstrated that late lumen volume loss following DCA was a result of a decrease in EEM volume. This was a late event, occurring between 1 and 6 months’ postintervention. |
---|---|
ISSN: | 0735-1097 1558-3597 |
DOI: | 10.1016/S0735-1097(98)00459-8 |