Hybrid endovascular operation for ruptured thoracic aortic aneurysm
The rupture of a thoracic aortic aneurysm is a life-threatening emergency. Conventional open surgical repair carries a high mortality and morbidity. We report an elderly patient who suffered from rupture of a proximal descending thoracic aortic aneurysm close to the aortic arch. A hybrid operation c...
Gespeichert in:
Veröffentlicht in: | Hong Kong medical journal = Xianggang yi xue za zhi 2007-02, Vol.13 (1), p.78-80 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The rupture of a thoracic aortic aneurysm is a life-threatening emergency. Conventional open surgical repair carries a high mortality and morbidity. We report an elderly patient who suffered from rupture of a proximal descending thoracic aortic aneurysm close to the aortic arch. A hybrid operation consisting of a right-to-left carotid bypass followed by endovascular repair of the descending thoracic aorta was carried out. The patient recovered uneventfully. A hybrid endovascular repair should be considered the treatment of choice for rupture of a thoracic aortic aneurysm near the arch. |
---|---|