Lateral vertebral assessment: a valuable technique to detect clinically significant vertebral fractures
Although many vertebral fractures are clinically silent, they are associated with increased risk for subsequent osteoporotic fractures. A substantial number of these fractures are demonstrable using instant vertebral assessment with Hologic densitometers. Whether similar recognition is possible usin...
Gespeichert in:
Veröffentlicht in: | Osteoporosis international 2005-12, Vol.16 (12), p.1513-1518 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Although many vertebral fractures are clinically silent, they are associated with increased risk for subsequent osteoporotic fractures. A substantial number of these fractures are demonstrable using instant vertebral assessment with Hologic densitometers. Whether similar recognition is possible using dual-energy lateral vertebral assessment (LVA) with GE Lunar densitometers remains uncertain. Thus, we evaluated the ability of clinicians using LVA to detect prevalent vertebral fractures. Dual-energy LVA and conventional thoracic and lumbar spine radiographs were concurrently obtained in 80 postmenopausal women. Using an established visual semiquantitative system, vertebral fractures were identified individually by two non-radiologist clinicians on LVA images, and the results were compared with spinal radiograph evaluation by an expert radiologist. Using LVA, 95% of vertebral bodies from T7 through L4 were evaluable, but a majority (66%) of vertebrae from T4 to T6 were not adequately visualized. In the LVA-evaluable vertebrae, prevalent fractures were identified in 40 vertebral bodies by radiography. In this regard, the clinicians using LVA detected 17 of 18 radiographically evident vertebral fractures of grade 2 or 3, a false negative rate of 6%. They identified 50% (11/22) of grade 1 fractures. Additionally, the vast majority of evaluable non-fractured vertebrae, (764/794, 96.2%) were correctly classified as normal by LVA. Thus, clinicians utilizing LVA correctly identified the vast majority of grade 2 or 3 vertebral compression fractures and normal vertebral bodies, although detection of grade 1 fractures was less effective. In conclusion, the low-radiation, dual-energy LVA technique provides a rapid and convenient way for clinicians to identify patients with, and without, grade 2 or 3 vertebral fractures, thereby enhancing care of osteoporotic patients. |
---|---|
ISSN: | 0937-941X 1433-2965 |
DOI: | 10.1007/s00198-005-1891-7 |