Balloon-assisted coil embolization of intracranial aneurysms : incidence, complications, and angiography results

The aim of this study was to assess the incidence, indications, complications, and angiography results associated with balloon-assisted coil embolization (BACE) of intracranial aneurysms and to compare these factors with those for conventional coil embolization (CE). Between 1995 and 2005, 827 intra...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of neurosurgery 2006-09, Vol.105 (3), p.396-399
Hauptverfasser: SLUZEWSKI, Menno, VAN ROOIJ, Willem Jan, BEUTE, Guus N, NUSSEN, Peter C
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The aim of this study was to assess the incidence, indications, complications, and angiography results associated with balloon-assisted coil embolization (BACE) of intracranial aneurysms and to compare these factors with those for conventional coil embolization (CE). Between 1995 and 2005, 827 intracranial aneurysms in 757 consecutive patients were packed with coils. Balloon-assisted coil embolization was used in 8.6% (71 of 827) of the coil insertion procedures and was more frequently used in large aneurysms, unruptured lesions, and those located on the vertebrobasilar system and carotid artery. Procedure-related complications leading to death or dependency were significantly higher in BACEs (14.1%) compared with those in CEs (3%). Packing densities and the results of 6-month follow-up angiography studies did not differ significantly between the two types of treatments. There was a strong trend for a higher retreatment rate in the aneurysms treated with BACE. Balloon-assisted coil embolization of intracranial aneurysms is associated with a high complication rate and should only be used if conventional CE of these lesions is impossible or has failed and if anticipated surgical risks are too high. The BACE procedure does not improve the occlusion rates of the aneurysms on follow-up evaluation.
ISSN:0022-3085
1933-0693