A novel method of removing artifacts because of metallic dental restorations in 3-D CT images of jaw bone
: CT images, especially in a three‐dimensional (3‐D) mode, give valuable information for oral implant surgery. However, image quality is often severely compromised by artifacts originating from metallic dental restorations, and an effective solution for artifacts is being sought. This study attempts...
Gespeichert in:
Veröffentlicht in: | Clinical oral implants research 2005-12, Vol.16 (6), p.728-735 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | : CT images, especially in a three‐dimensional (3‐D) mode, give valuable information for oral implant surgery. However, image quality is often severely compromised by artifacts originating from metallic dental restorations, and an effective solution for artifacts is being sought. This study attempts to substitute the damaged areas of the jaw bone images with dental cast model images obtained by CT. The position of the dental cast images was registered to that of the jaw bone images using a devised interface that is composed of an occlusal bite made of self‐curing acrylic resin and a marker plate made of gypsum. The patient adapted this interface, and CT images of the stomatognathic system were filmed. On the other hand, this interface was placed between the upper and lower cast models and filmed by CT together with the cast models. The position of the marker plate imaged with the dental casts was registered to those adapted by the patient. The error of registration was examined to be 0.25 mm, which was satisfactory for clinical application. The damaged region in the cranial bone images as an obstacle for implant surgery was removed and substituted with the trimmed images of the dental cast. In the method developed here, the images around the metallic compounds severely damaged by artifacts were successfully reconstructed, and the stomatognathic system images became clear, and this is useful for implant surgery.
Résumé
Des images CT spécialement en 3D donnent une information très précise pour la chirurgie implantaire buccale. Cependant la qualité d'image est souvent fortement compromise par des artefacts provenant de restaurations dentaires métalliques; une solution efficace contre ces artefacts est toujours recherchée. Cette étude a essayé de remplacer les zones abîmées des images osseuses de la mâchoire par un modèle dentaire avec image obtenue par CT. La position des images du modèle dentaire était reliée à celles des images de l'os de la mâchoire en utilisant une interface qui était composée d'un mordu occlusal fabriqué avec de la résine acrylique autopolymérisante et d'un plateau marqueur faits de gypse. Le patient adaptéà cette interface et les images CT du système stomatognatique étaient filmés. D'un autre côté, cette interface était placée entre les modèles supérieurs et inférieurs et filmés par CT avec les modèles. La position du plateau marqueur filmé avec les modèles dentaires a été enregistrée avec celle adaptée au patient. L'erreur d'enregistre |
---|---|
ISSN: | 0905-7161 1600-0501 |
DOI: | 10.1111/j.1600-0501.2005.01139.x |