Evaluation of the Sexual Assessment Monitor, a diagnostic device used to electronically quantify ejaculatory latency time: findings from three studies

Associate Editor Michael G. Wyllie Editorial Board Ian Eardley, UK Jean Fourcroy, USA Sidney Glina, Brazil Julia Heiman, USA Chris McMahon, Australia Bob Millar, UK Alvaro Morales, Canada Michael Perelman, USA Marcel Waldinger, Netherlands OBJECTIVE To validate the Sexual Assessment Monitor (SAM), a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:BJU international 2006-09, Vol.98 (3), p.613-618
Hauptverfasser: DINSMORE, WALLACE W., RALPH, DAVID J., KELL, PHILLIP, WYLIE, KEVAN R., DEAN, JOHN P., NOVAK, CLAIRE, WYLLIE, JENNIFER S., WYLLIE, MICHAEL G.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Associate Editor Michael G. Wyllie Editorial Board Ian Eardley, UK Jean Fourcroy, USA Sidney Glina, Brazil Julia Heiman, USA Chris McMahon, Australia Bob Millar, UK Alvaro Morales, Canada Michael Perelman, USA Marcel Waldinger, Netherlands OBJECTIVE To validate the Sexual Assessment Monitor (SAM), a novel apparatus designed to collect electronic data on ejaculatory latency time (ELT) for diagnosing premature ejaculation (PE), and for accurately measuring treatment outcomes in clinical trials. PATIENTS, SUBJECTS AND METHODS Men with PE, and healthy volunteers aged 18–75 years, were enrolled in three open‐label studies, conducted in the UK. The SAM, which consists of a control box with two front attachments, a vibrator and sensor, was attached to the penis. The vibrator, which provides stimulation, was positioned at the frenulum using a soft cuff; the vibrator intensity was set at 80 units for most subjects. The sensor is an indium‐gallium elasticated loop, which was positioned around the base of the penis to detect ejaculatory pulses. These pulses were transmitted to a data recorder in the control box. The data, which are displayed graphically as traces, were automatically classified by a computer‐generated algorithm to quantify ELT. RESULTS In all, 53 healthy volunteers and 58 men with PE provided 213 and 195 evaluable records, respectively. Most were complete records (99% and 96%). The pooled data showed that the ELT was much higher for healthy volunteers than for men with PE (geometric means: 687 vs 169 s, respectively), with a healthy volunteer to PE patient ratio of 2.87 (P 
ISSN:1464-4096
1464-410X
DOI:10.1111/j.1464-410X.2006.06286.x