Pioglitazone reduces neointima volume after coronary stent implantation : A randomized, placebo-controlled, double-blind trial in nondiabetic patients

Restenosis requiring reintervention limits the long-term success after coronary stent implantation. Thiazolidinediones, like pioglitazone or rosiglitazone, are oral antidiabetic drugs with additional antirestenotic properties. In a randomized, placebo-controlled, double-blind trial, we examined the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Circulation (New York, N.Y.) N.Y.), 2005-11, Vol.112 (18), p.2792-2798
Hauptverfasser: MARX, Nikolaus, WÖHRLE, Jochen, NUSSER, Thorsten, WALCHER, Daniel, RINKER, Angelika, HOMBACH, Vinzenz, KOENIG, Wolfgang, HÖHER, Martin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Restenosis requiring reintervention limits the long-term success after coronary stent implantation. Thiazolidinediones, like pioglitazone or rosiglitazone, are oral antidiabetic drugs with additional antirestenotic properties. In a randomized, placebo-controlled, double-blind trial, we examined the effect of 6-month pioglitazone therapy on neointima volume after coronary stenting in nondiabetic coronary artery disease patients. Fifty nondiabetic patients after coronary stent implantation were randomly assigned to pioglitazone (30 mg daily; pio) or placebo (control) treatment in addition to standard therapy, and neointima volume was assessed by intravascular ultrasound at the 6-month follow-up. Both groups were comparable with regard to baseline characteristics, angiographic lesion morphology, target vessel, and length of the stented segment. In addition, there were no statistical differences in minimal lumen diameter before and after intervention, as well as reference diameter after stent implantation. In this study population of nondiabetic patients, pio treatment did not significantly change fasting blood glucose, fasting insulin, or glycosylated hemoglobin levels, as well as lipid parameters. In contrast, pio treatment significantly reduced neointima volume within the stented segment, with 2.3+/-1.1 mm3/mm in the pio group versus 3.1+/-1.6 mm3/mm in controls (P=0.04). Total plaque volume (adventitia-lumen area) was significantly lower at follow-up in the pio group (11.2+/-3.2 mm3/mm) compared with controls (13.2+/-4.2 mm3/mm; P=0.04). Moreover, the binary restenosis rate was 3.4% in the pio group versus 32.3% in controls (P
ISSN:0009-7322
1524-4539
DOI:10.1161/CIRCULATIONAHA.105.535484