Critical Laboratory Value Notification: A Failure Mode Effects and Criticality Analysis

The Failure Mode Effects and Criticality Analysis (FMECA) was applied to improve the timeliness of reporting and the timeliness of receipt by the responsible licensed caregiver of critical laboratory values (CLVs) for outpatients and non–critical care inpatients. Through a risk prioritization proces...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Joint Commission journal on quality and patient safety 2005-09, Vol.31 (9), p.495-506
Hauptverfasser: Saxena, Sunita, Kempf, Raymond, Wilcox, Susan, Shulman, Ira A., Wong, Louise, Cunningham, Glenn, Vega, Elaine, Hall, Stephanie
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The Failure Mode Effects and Criticality Analysis (FMECA) was applied to improve the timeliness of reporting and the timeliness of receipt by the responsible licensed caregiver of critical laboratory values (CLVs) for outpatients and non–critical care inpatients. Through a risk prioritization process, the most important areas for improvement, including contacting the provider, assisting the provider in contacting the patient, and educating the provider in follow-up options available during off hours, were identified. A variety of systemic improvements were made; for example, the CLV notification process was centralized in the customer service center, with databases to help providers select options and make arrangements for follow-up care and an electronic abstract form to document the CLV notification process. Review of documentation and appropriateness of CLV follow-up care was integrated into the quality monitoring process to detect any variations or problems. The average CLV notification time for the month steadily declined during an eight-month period. Compliance was 100% for the “read-back” requirement and documentation in patient’s health record. This proactive risk assessment project successfully modified the CLV notification program from a high- to a low-risk process, identified activities to further improve the process, and helped ensure compliance with a variety of requirements.
ISSN:1553-7250
1938-131X
DOI:10.1016/S1553-7250(05)31064-6