Sensitization Following LVAD Implantation Using Leucodepleted Blood Is Not Due to HLA Antibodies

Implantation of left ventricular assist devices (LVAD) is associated with HLA antibody sensitization. The objective of this study was to determine the specificity of antibodies produced by LVAD recipients using a combination of ELISA, Luminex and microcytotoxicity assays. Fifty‐one LVAD patients wer...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of transplantation 2006-07, Vol.6 (7), p.1712-1717
Hauptverfasser: Newell, H., Smith, J. D., Rogers, P., Birks, E., Danskine, A. J., Fawson, R. E., Rose, M. L.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Implantation of left ventricular assist devices (LVAD) is associated with HLA antibody sensitization. The objective of this study was to determine the specificity of antibodies produced by LVAD recipients using a combination of ELISA, Luminex and microcytotoxicity assays. Fifty‐one LVAD patients were studied, from 44 to 838 days post‐implantation. No patient developed HLA antibodies, although 24 produced IgG antibodies detectable in both ELISA and Luminex assays. These antibodies manifest as positive reactions with class I and class II wells of the ELISA and also blank wells. In Luminex assays, they produce high MFI readings with the negative control beads. Antibodies were detected 18 to 228 days after implantation. This reactivity was found to be directed against bovine serum albumin (BSA), commonly used to block non‐specific binding in ELISA and Luminex assays; absorption of sera with BSA‐coated beads completely abrogated reactivity in all solid phase assays, but did not eliminate anti‐HLA antibodies in control sera. Ten of the 24 patients have proceeded to transplantation, with a 1‐year graft survival of 69%. In conclusion, it appears that implantation of LVADS disrupts immunoregulatory pathways leading to production of anti‐albumin antibodies. These can be misinterpreted as anti‐HLA antibodies in solid phase assays. In 51 patients receiving left ventricular assist devices, no patient developed HLA antibodies but 24 produced antibodies against albumin which masqueraded as antibodies against HLA in solid phase antibody assays.
ISSN:1600-6135
1600-6143
DOI:10.1111/j.1600-6143.2006.01342.x