Verification of the exponential model of body temperature decrease after death in pigs
The authors have conducted a systematic study in pigs to verify the models of post-mortem body temperature decrease currently employed in forensic medicine. Twenty-four hour automatic temperature recordings were performed in four body sites starting 1.25 h after pig killing in an industrial slaughte...
Gespeichert in:
Veröffentlicht in: | Experimental physiology 2005-09, Vol.90 (5), p.727-738 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The authors have conducted a systematic study in pigs to verify the models of post-mortem body temperature decrease currently
employed in forensic medicine. Twenty-four hour automatic temperature recordings were performed in four body sites starting
1.25 h after pig killing in an industrial slaughterhouse under typical environmental conditions (19.5â22.5°C). The animals
had been randomly selected under a regular manufacturing process. The temperature decrease time plots drawn starting 75 min
after death for the eyeball, the orbit soft tissues, the rectum and muscle tissue were found to fit the single-exponential
thermodynamic model originally proposed by H. Rainy in 1868. In view of the actual intersubject variability, the addition
of a second exponential term to the model was demonstrated to be statistically insignificant. Therefore, the two-exponential
model for death time estimation frequently recommended in the forensic medicine literature, even if theoretically substantiated
for individual test cases, provides no advantage as regards the reliability of estimation in an actual case. The improvement
of the precision of time of death estimation by the reconstruction of an individual curve on the basis of two dead body temperature
measurements taken 1 h apart or taken continuously for a longer time (about 4 h), has also been proved incorrect. It was demonstrated
that the reported increase of precision of time of death estimation due to use of a multiexponential model, with individual
exponential terms to account for the cooling rate of the specific body sites separately, is artifactual. The results of this
study support the use of the eyeball and/or the orbit soft tissues as temperature measuring sites at times shortly after death.
A single-exponential model applied to the eyeball cooling has been shown to provide a very precise estimation of the time
of death up to approximately 13 h after death. For the period thereafter, a better estimation of the time of death is obtained
from temperature data collected from the muscles or the rectum. |
---|---|
ISSN: | 0958-0670 1469-445X |
DOI: | 10.1113/expphysiol.2005.030551 |