Intraoperative latex hypersensitivity: do not overlook Penrose drains
We report a case of intraoperative latex hypersensitivity to Penrose surgical drains (Ansell, Massillon, Ohio). To our knowledge, there has been no previous report of such a reaction with this device.
Gespeichert in:
Veröffentlicht in: | Journal of clinical anesthesia 2005-09, Vol.17 (6), p.485-487 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We report a case of intraoperative latex hypersensitivity to Penrose surgical drains (Ansell, Massillon, Ohio). To our knowledge, there has been no previous report of such a reaction with this device. |
---|---|