Regeneration of articular cartilage – Evaluation of osteochondral defect repair in the rabbit using multiphasic implants
To investigate whether two different multiphasic implants could initiate and sustain repair of osteochondral defects in rabbits. The implants address the malleable properties of cartilage while also addressing the rigid characteristics of subchondral bone. The bone region of both devices consisted o...
Gespeichert in:
Veröffentlicht in: | Osteoarthritis and cartilage 2005-09, Vol.13 (9), p.798-807 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To investigate whether two different multiphasic implants could initiate and sustain repair of osteochondral defects in rabbits. The implants address the malleable properties of cartilage while also addressing the rigid characteristics of subchondral bone.
The bone region of both devices consisted of
d,
d–
l,
l-polylactic acid invested with hyaluronan (HY). The cartilage region of the first device was a polyelectrolytic complex (PEC) hydrogel of HY and chitosan. In the second device the cartilage region consisted of type I collagen scaffold. Eighteen rabbits were implanted bilaterally with a device, or underwent defect creation with no implant. At 24 weeks, regenerated tissues were evaluated grossly, histologically and via immunostaining for type II collagen.
PEC devices induced a significantly better repair than untreated shams. Collagen devices resulted in a quality of repair close to that of the PEC group, although its mean repair score (19.0
±
4.2) did not differ significantly from that of the PEC group (20.4
±
3.7) or the shams (16.5
±
6.3). The percentage of hyaline-appearing cartilage in the repair was highest with collagen implants, while the degree of bonding of repair to the host, structural integrity of the neocartilage, and reconstitution of the subchondral bone was greatest with PEC devices. Cartilage in both device-treated sites stained positive for type II collagen and GAG.
Both implants are capable of maintaining hyaline-appearing tissue at 24 weeks. The physicochemical region between the cartilage and bone compartments makes these devices well suited for delivery of different growth factors or drugs in each compartment, or different doses of the same factor. It also renders these devices excellent vehicles for chondrocyte or stem cell transplantation. |
---|---|
ISSN: | 1063-4584 1522-9653 |
DOI: | 10.1016/j.joca.2005.04.018 |