Ossiculoplasty with intact stapes and absent malleus: the silastic banding technique
To report an original method of ossicular reconstruction with intact stapes and absent malleus. Ossiculoplasty is performed with a total ossicular replacement prosthesis positioned from the stapes footplate to the under-surface of the tympanic membrane, using a Silastic banding technique to stabiliz...
Gespeichert in:
Veröffentlicht in: | Otology & neurotology 2005-09, Vol.26 (5), p.846-852 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To report an original method of ossicular reconstruction with intact stapes and absent malleus. Ossiculoplasty is performed with a total ossicular replacement prosthesis positioned from the stapes footplate to the under-surface of the tympanic membrane, using a Silastic banding technique to stabilize the prosthesis.
A prospective study of ossicular reconstruction using the Silastic banding technique. A consecutive series of cases with intact stapes superstructure and missing malleus handle (Austin-Kartush Group C) is presented.
One tertiary referral center.
Ninety-nine patients who underwent total ossicular reconstruction with Silastic banding technique were enrolled in the study from January 2000 to December 2002.
Ossiculoplasty with total ossicular replacement prostheses with Silastic Rubber Band for chronic otitis media and non-inflammatory disease.
Preoperative and postoperative audiometric evaluation using conventional audiometry. Air-bone gap, bone-conduction threshold, and air-conduction threshold were assessed. Postoperative audiometry was performed at the 6th, 9th, 12th, 18th, 24th, and 36th months.
Overall, a postoperative air-bone gap closed to within 10 dB was achieved in 61.5% of cases. An air-bone gap smaller than 20 dB was obtained in 77% of cases. Postoperative improvement of air-conduction thresholds by at least 20 dB was found in 51% of cases. There was no case of postoperative sensorineural hearing loss. One case of extrusion of the prosthesis was seen (1%).
Stabilizing the total ossicular replacement prosthesis with the Silastic banding technique when performing ossicular reconstruction is a safe, effective method when the stapes supra-structure is present and the malleus absent. |
---|---|
ISSN: | 1531-7129 |