Aortic and Mitral Valve Replacement in a Patient with Hemophilia B

A 25-year-old man with factor IX deficiency had an aortic and mitral valve replacement using a 2M Starr Edwards valve in the mitral position and a 22 Medtronic valve in the aortic position under cover of factor IX concentrate. The surgical procedure and the immediate postoperative period were uneven...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Asian cardiovascular & thoracic annals 2007-12, Vol.15 (6), p.526-527
Hauptverfasser: Thankachen, Roy, George, Biju, Shukla, Vinayak, Korula, Roy J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A 25-year-old man with factor IX deficiency had an aortic and mitral valve replacement using a 2M Starr Edwards valve in the mitral position and a 22 Medtronic valve in the aortic position under cover of factor IX concentrate. The surgical procedure and the immediate postoperative period were uneventful except for a pericardial effusion which required a pericardiostomy. He was anticoagulated with heparin in the immediate postoperative period while the factor IX concentrate was being administered. Oral anticoagulation with acenocoumarol (Acitrom®) was started, maintaining the international normalized ratio between 1.5 and 2. He was doing well at follow-up 9 months later.
ISSN:0218-4923
1816-5370
DOI:10.1177/021849230701500618