Determination of solifenacin succinate, a novel muscarinic receptor antagonist, and its major metabolite in rat plasma by semi-micro high performance liquid chromatography
A sensitive and specific method for the simultaneous determination of the unchanged drug (solifenacin) and its major metabolite (M1, 4 S-hydroxy solifenacin) in rat plasma was developed and validated. Both solifenacin and M1 were extracted from rat plasma by a two-step liquid–liquid extraction and a...
Gespeichert in:
Veröffentlicht in: | Journal of chromatography. B, Analytical technologies in the biomedical and life sciences Analytical technologies in the biomedical and life sciences, 2007-11, Vol.859 (2), p.241-245 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A sensitive and specific method for the simultaneous determination of the unchanged drug (solifenacin) and its major metabolite (M1, 4
S-hydroxy solifenacin) in rat plasma was developed and validated. Both solifenacin and M1 were extracted from rat plasma by a two-step liquid–liquid extraction and analyzed by semi-micro HPLC with UV detection at an absorbance wavelength of 220
nm. The chromatographic separations were performed on a TSKgel ODS-80Ts (5
μm, 150
mm
×
2.0
mm i.d.) reversed-phase column with a mobile phase of 0.1
M phosphate buffer (pH 3.0):acetonitrile (71:29, v/v). The intra-day precision (expressed as coefficient of variation, CV) ranged from 0.4% to 1.7%, and the accuracy (expressed as relative error, RE) ranged from −5.2% to 2.0% for solifenacin. The corresponding precision ranged from 1.3% to 3.2%, and accuracy ranged from −4.0% to 8.6% for M1. The lower limit of quantitation for both solifenacin and M1 was 2
ng/ml when 1
ml of plasma was used. No endogenous interference was observed in rat plasma. |
---|---|
ISSN: | 1570-0232 1873-376X |
DOI: | 10.1016/j.jchromb.2007.10.005 |