Model for predicting comprehensive two-dimensional gas chromatography retention times

A model for approximating the relative retention of solutes in comprehensive two-dimensional gas chromatography (GC × GC) is presented. The model uses retention data from standard single-column temperature-programmed separations. The one-dimensional retention times are first converted into retention...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Chromatography A 2007-11, Vol.1172 (1), p.72-83
Hauptverfasser: Seeley, John V., Seeley, Stacy K.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A model for approximating the relative retention of solutes in comprehensive two-dimensional gas chromatography (GC × GC) is presented. The model uses retention data from standard single-column temperature-programmed separations. The one-dimensional retention times are first converted into retention indices and then these indices are combined in a simple manner to generate a retention diagram. A retention diagram is an approximation of the two-dimensional chromatogram that has retention order and spacing in both dimensions similar to that found in the experimental chromatogram. If required, the retention diagram can be scaled to more closely resemble the two-dimensional chromatogram. The model has been tested by using retention time data from single-column gas chromatography–mass spectrometry and valve-based GC × GC. A total of 139 volatile organic compounds (VOCs) were examined. Approximately half of the VOCs had a single functional group and a linear alkyl chain (i.e., compounds with the structure Z (CH 2) n H). The retention diagrams had primary retention orders that were in excellent agreement with the GC × GC chromatograms. The relative secondary retention order for compounds with similar structures was also accurately predicted by the retention diagram. However, the relative secondary retention for compounds with dissimilar structures, such as acyclic alcohols and multi-substituted alkylbenzenes, were less accurately modeled. This study demonstrates how readily available single-column retention time data can be used to provide an a priori estimate of the relative retention of solutes in a GC × GC chromatogram. Such a capability is useful for screening possible combinations of stationary phases.
ISSN:0021-9673