Dual-chamber epicardial pacing in neonates with congenital heart block
Objective This review evaluates the outcome of a treatment strategy using dual-chamber pacemakers for neonates with congenital heart block. Methods From 1989 to 2006, 10 neonates had dual-chamber epicardial pacemaker placement for congenital heart block. Mean age and weight were 4.4 ± 5.6 days and 2...
Gespeichert in:
Veröffentlicht in: | The Journal of thoracic and cardiovascular surgery 2007-11, Vol.134 (5), p.1188-1192 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objective This review evaluates the outcome of a treatment strategy using dual-chamber pacemakers for neonates with congenital heart block. Methods From 1989 to 2006, 10 neonates had dual-chamber epicardial pacemaker placement for congenital heart block. Mean age and weight were 4.4 ± 5.6 days and 2.8 ± 0.6 kg. Four patients had heterotaxy syndrome and required concomitant cardiac procedures. One patient had fetal hydrops, myocarditis, and cardiomyopathy. Five patients had structurally normal hearts. Sternotomy (2 partial, 8 full) and unipolar leads (2 non–steroid eluting, 18 steroid-eluting) were used in all. Generators were placed in submuscular bilateral rectus sheath pockets. Results Successful atrioventricular synchrony was established in all patients. Mean P-wave sensing was 4.7 ± 2.6 mV and atrial voltage threshold was 0.8 ± 0.3 V. Mean R-wave sensing was 13.0 ± 5.7 mV and ventricular voltage threshold 0.9 ± 0.5 V. There were no wound complications or acute lead failures. Median postoperative stay was 14 days. Three of the 4 patients with heterotaxy died at 3 days, 14 days, and 15 months postoperatively. The patient with cardiomyopathy died suddenly at 6 months of acute myocarditis. No patient with a structurally normal heart died ( P < .05). Mean follow-up interval in survivors is 6.1 ± 7.1 years with 1 patient lost to follow-up. Conclusions Implantation of a dual-chamber epicardial pacemaker in neonates with congenital heart block is technically feasible and results in excellent outcomes in patients with structurally normal hearts. System longevity at 6 years is excellent. Patients with congenital heart block and heterotaxy syndrome have a poor prognosis despite dual-chamber pacing. |
---|---|
ISSN: | 0022-5223 1097-685X |
DOI: | 10.1016/j.jtcvs.2007.04.049 |