Prenatal diagnosis for organic acid disorders using two mass spectrometric methods, gas chromatography mass spectrometry and tandem mass spectrometry
We performed prenatal diagnosis of organic acid disorders using two mass spectrometric methods; gas chromatography mass spectrometry (GC/MS) and tandem mass spectrometry (ESI/MS/MS). Of 28 cases whose amniotic fluid was tested, 11 cases were diagnosed as “affected”. All cases whose samples were diag...
Gespeichert in:
Veröffentlicht in: | Journal of chromatography. B 2005-08, Vol.823 (1), p.13-17 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We performed prenatal diagnosis of organic acid disorders using two mass spectrometric methods; gas chromatography mass spectrometry (GC/MS) and tandem mass spectrometry (ESI/MS/MS). Of 28 cases whose amniotic fluid was tested, 11 cases were diagnosed as “affected”. All cases whose samples were diagnosed as “unaffected” were confirmed to have no symptoms or abnormalities in urinary organic acid analysis after birth. Of the 11 “affected” cases, two cases were missed by ESI/MS/MS but not by GC/MS. When the stability of metabolites in amniotic fluid was checked, it was found that acylcarnitines degraded in one week at room temperature, whereas organic acids such as methylmalonate or methylcitrate were stable for at least 14 days. Prenatal diagnosis by analysis using simultaneous two or more methods may be more reliable, though attention should be paid to sample transportation conditions. |
---|---|
ISSN: | 1570-0232 1873-376X |
DOI: | 10.1016/j.jchromb.2005.04.020 |