Mallet fractures: A novel approach to internal fixation using a hook plate
A new treatment of mallet fractures of the distal phalanx is presented. Open reduction and internal fixation was performed using a “hook” plate fabricated from a 1.3 mm AO hand modular system straight plate. This technique avoids the need to place implants or wires through the small avulsion fragmen...
Gespeichert in:
Veröffentlicht in: | Journal of hand surgery, British volume British volume, 2007-02, Vol.32 (1), p.24-30 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A new treatment of mallet fractures of the distal phalanx is presented. Open reduction and internal fixation was performed using a “hook” plate fabricated from a 1.3
mm AO hand modular system straight plate. This technique avoids the need to place implants or wires through the small avulsion fragment while still being able to achieve a stable “tension-plate” type of fixation construct strong enough to allow protected early active motion of the distal interphalangeal joint. In minimising the need for prolonged splinting, patient comfort is also improved. In a consecutive series of nine fractures, union was achieved in all cases. At an average follow-up period of 17 months, four had excellent and five had good results using the Crawford rating scale. Using the Warren and Norris scale, all patients had a successful result. The final average active range of flexion of the distal interphalangeal joint was 64° and there was no extensor lag. |
---|---|
ISSN: | 0266-7681 1753-1934 1532-2211 2043-6289 |
DOI: | 10.1016/j.jhsb.2006.09.007 |