On-line coupling of sequential injection extraction with restricted-access materials and post-column derivatization for sample clean-up and determination of propranolol in human plasma
The presented paper deals with a new methodology for direct determination of propranolol in human plasma. The methodology described is based on sequential injection analysis technique (SIA) coupled with solid phase extraction (SPE) column based on restricted access materials (RAM). Special RAM colum...
Gespeichert in:
Veröffentlicht in: | Analytica chimica acta 2007-09, Vol.600 (1), p.122-128 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The presented paper deals with a new methodology for direct determination of propranolol in human plasma. The methodology described is based on sequential injection analysis technique (SIA) coupled with solid phase extraction (SPE) column based on restricted access materials (RAM). Special RAM column containing 30
μm polymeric material—
N-vinylacetamide copolymer was integrated into the sequential injection manifold. SIA–RAM system was used for selective retention of propranolol, while the plasma matrix components were eluted with two weak organic solutions to waste.
Due to the acid–basic and polarity properties of propranolol molecule and principles of reversed-phase chromatography, it was possible to retain propranolol on the
N-vinylacetamide copolymer sorbent (Shodex MSpak PK-2A 30
μm (2
mm
×
10
mm)). Centrifuged plasma samples were aspirated into the system and loaded onto the column using acetonitrile–water (5:95, v/v), pH 11.00, adjusted by triethylamine. The analyte was retained on the column while proteins contained in the sample were removed to waste. Interfering endogenous substances complicating detection were washed out by acetonitrile–water (15:85), pH 11.00 in the next step. The extracted analyte was eluted by means of tetrahydrofuran–water (25:75), pH 11.00 to the fluorescence detector (emission filter 385
nm). The whole procedure comprising sample pre-treatment, analyte detection and column reconditioning took about 15
min. The recoveries of propranolol from undiluted plasma were in the range 96.2–97.8% for three concentration levels of analyte. The proposed SIA–RAM method has been applied for direct determination of propranolol in human plasma. |
---|---|
ISSN: | 0003-2670 1873-4324 |
DOI: | 10.1016/j.aca.2007.02.021 |