Electrical Impedance of the Liver During Experimental Long-Term Liver Preservation

Abstract Measurements of electrical impedance were performed to assess ischemic damage in the rabbit liver during long-term preservation with University of Wisconsin (UW) or histidine-tryptophan-ketoglutarate (HTK) solution. The impedance was measured at a frequency of 200 Hz after in situ perfusion...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Transplantation proceedings 2007-09, Vol.39 (7), p.2118-2119
Hauptverfasser: Cascales-Sanchez, P, Fernandez-Cornejo, V, Tomas-Gomez, A, Terol-Calpena, F, Sanchez-Del Campo, F
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Measurements of electrical impedance were performed to assess ischemic damage in the rabbit liver during long-term preservation with University of Wisconsin (UW) or histidine-tryptophan-ketoglutarate (HTK) solution. The impedance was measured at a frequency of 200 Hz after in situ perfusion and after cold storage for 24 and 48 hours in UW or HTK solution (six livers per group). Z200Hz was significantly higher ( P < .01) after 48 compared with 24 hours of cold storage with both protection solutions without significant differences between the livers preserved with both solutions. Electrical impedance was observed to be a sensitive indicator of liver damage during long-term protection, showing similar preservation quality for both preservation solutions.
ISSN:0041-1345
1873-2623
DOI:10.1016/j.transproceed.2007.06.053