Mis-identification of factor inhibitors by diagnostic haemostasis laboratories: recognition of pitfalls and elucidation of strategies. A follow up to a large multicentre evaluation
We previously reported the ability of diagnostic haemostasis facilities to identify coagulation factor abnormalities and inhibitors, through a large multi-centre study conducted on behalf of the Royal College of Pathologists of Australasia (RCPA) Quality Assurance Program (QAP). In the current repor...
Gespeichert in:
Veröffentlicht in: | Pathology 2007-10, Vol.39 (5), p.504-511 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We previously reported the ability of diagnostic haemostasis facilities to identify coagulation factor abnormalities and inhibitors, through a large multi-centre study conducted on behalf of the Royal College of Pathologists of Australasia (RCPA) Quality Assurance Program (QAP). In the current report, additional data evaluation aims to (1) help identify the reasons behind the failures in inhibitor identification, (2) highlight the pitfalls in inhibitor testing, and (3) help elucidate some strategies for overcoming these problems and to assist in better identification and characterisation of inhibitors.
Forty-two laboratories blind tested a set of eight samples for the presence or absence of inhibitors. These included true factor inhibitors (FVIII and FV), and other samples that reflected potential pre-analytical variables (e.g., heparin contamination, serum, EDTA plasma, aged plasma) that might arise and complicate inhibitor detection or lead to false inhibitor identification.
There was a wide scatter of inhibitor results, with false positive and false negative inhibitor identification, and mis-identification of inhibitors (e.g., FVIII inhibitor identified where FV inhibitor present). Further analysis of the pattern of reported laboratory results, including routine coagulation testing and factor profiles, allowed some additional interpretative power to provide strategies that will assist laboratories to improve the accuracy of inhibitor identification in the future.
There are currently occasional lapses in factor inhibitor identification, which this report will hopefully help address. |
---|---|
ISSN: | 0031-3025 1465-3931 |
DOI: | 10.1080/00313020701569998 |