Development of LC/MS/MS assay for the determination of 5-ethyl-2-{5-[4-(2-hydroxyethyl)piperazine-1-sulfonyl]-2-propoxyphenyl}-7-propyl-3,5-dihydropyrrolo[3,2-d]pyrimidin-4-one (SK3530) in human plasma: application to a clinical pharmacokinetic study
5-Ethyl-2-{5-[4-(2-hydroxyethyl)piperazine-1-sulfonyl]-2-propoxyphenyl}-7-propyl-3,5-dihydropyrrolo[3,2-d]pyrimidin-4-one (SK3530) is a new phosphodiesterase type-5 inhibitor currently undergoing a Phase III investigation for the treatment of male erectile dysfunction. This study first describes a r...
Gespeichert in:
Veröffentlicht in: | Journal of pharmaceutical and biomedical analysis 2007-09, Vol.45 (1), p.176-184 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | 5-Ethyl-2-{5-[4-(2-hydroxyethyl)piperazine-1-sulfonyl]-2-propoxyphenyl}-7-propyl-3,5-dihydropyrrolo[3,2-d]pyrimidin-4-one (SK3530) is a new phosphodiesterase type-5 inhibitor currently undergoing a Phase III investigation for the treatment of male erectile dysfunction. This study first describes a rapid and sensitive LC/MS/MS assay method for the quantification of SK3530 and its major metabolite, SK3541, in human plasma. The assay was validated to demonstrate the specificity, linearity, recovery, lower limit of quantification (LLOQ), accuracy, and precision. The multiple reaction monitoring was based on the transition of m/z=532.5→99.1 for SK3530, 488.6→295.5 for SK3541, and 520.3→99.1 for SK3304 (internal standard). The assay utilized a single liquid–liquid extraction and isocratic elution, and the LLOQ was 1ng/ml using 0.2ml human plasma. The assay was linear over a range from 1 to 1000ng/ml for both SK3530 and SK3541, with correlation coefficients >0.9999. The mean intra- and inter-day assay accuracy ranged from 94.7 to 101.6% and 96.8 to 101.1% for SK3530 and 92.6–105.7% and 97.4–107.8% for SK3541, respectively. The mean intra- and inter-day precision was between 7.2–12.1% and 5.7–7.4% for SK3530 and 4.6–13.2% and 5.0–14.1% for SK3541, respectively. The developed assay was applied to a clinical pharmacokinetic study after oral administration of SK3530 in healthy male volunteers (dose 100mg). |
---|---|
ISSN: | 0731-7085 1873-264X |
DOI: | 10.1016/j.jpba.2007.06.021 |