Preoperative Testing for Sepsis Before Revision Total Knee Arthroplasty
Abstract One hundred five consecutive painful knee arthroplasties were evaluated by a single surgeon for the presence of infection using a uniform protocol that included an erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), perioperative aspiration with synovial fluid white blood cell (...
Gespeichert in:
Veröffentlicht in: | The Journal of arthroplasty 2007-09, Vol.22 (6), p.90-93 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract One hundred five consecutive painful knee arthroplasties were evaluated by a single surgeon for the presence of infection using a uniform protocol that included an erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), perioperative aspiration with synovial fluid white blood cell (WBC) count and differential, intraoperative frozen section analysis, and culture. A synovial fluid WBC count of greater than 3000 was the most precise test with a sensitivity of 100%, specificity of 98%, and accuracy of 99%. The preoperative use of an ESR and CRP proved to be an excellent screening modality with only one infection identified with both values being normal. A rational approach to perioperative testing for sepsis includes a screening ESR and CRP, and if elevated, aspiration with synovial fluid WBC count or an intraoperative frozen section. |
---|---|
ISSN: | 0883-5403 1532-8406 |
DOI: | 10.1016/j.arth.2007.04.013 |