Prospective cohort study of central venous catheters among internal medicine ward patients

Central venous catheter (CVC) use is less well described for patients outside the intensive care unit. We evaluated CVCs and the associated bloodstream infection rate among patients admitted to the general medical service. We performed a prospective cohort study of patients who had a CVC on admissio...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of infection control 2006-12, Vol.34 (10), p.636-641
Hauptverfasser: Trick, William E., Miranda, Julio, Evans, Arthur T., Charles-Damte, Marjorie, Reilly, Brendan M., Clarke, Peter
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Central venous catheter (CVC) use is less well described for patients outside the intensive care unit. We evaluated CVCs and the associated bloodstream infection rate among patients admitted to the general medical service. We performed a prospective cohort study of patients who had a CVC on admission or inserted during their stay on the general medical service in a public teaching hospital, November 15, 2004, to March 31, 2005. We identified 106 CVCs, 52 were present on admission and 54 were inserted; there were 682 catheter-days. The primary bloodstream infection rate was 4.4 per 1000 catheter-days (95% CI: 0.9-13): highest for catheters inserted in the emergency department compared with those inserted on other units (24 vs 1.7 per 1000 catheter-days), P = .045. By multivariable analysis, inadequate dressings were more likely among patients with a body mass index ≥30 kg/m 2, adjusted odds ratio, 3.4 (95% CI: 1.4-8.0). Many CVCs had previously been inserted in the emergency department or intensive care unit; therefore, strategies to reduce bloodstream infections that focus on ward insertion practices may not dramatically reduce bloodstream infection rates. Intervention strategies should target improved dressing care and consideration of early removal or replacement of catheters inserted in the emergency department.
ISSN:0196-6553
1527-3296