Analysis of fiducial markers used for on-line verification in the external-beam radiotherapy of patients with cranial tumours
Evaluate the fiducial marker-based position verification in the external-beam radiotherapy of patients with cranial tumour. Thirteen patients with intracranial tumours were treated with external- beam radiotherapy using 3 gold markers implanted in the skull. Before each fraction the patient was posi...
Gespeichert in:
Veröffentlicht in: | Clinical & translational oncology 2007-08, Vol.9 (8), p.531-536 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Evaluate the fiducial marker-based position verification in the external-beam radiotherapy of patients with cranial tumour.
Thirteen patients with intracranial tumours were treated with external- beam radiotherapy using 3 gold markers implanted in the skull. Before each fraction the patient was positioned on the treatment table and 2 orthogonal portal images were performed to localise the 3 gold seeds and the target position was calculated using a commercialised computer program (ISOLOC software, MEDTEC). This program provides the couch movements required to move the target to the isocentre.
When the set-up error was corrected using the coordinates of the 3 markers, the final movements were less than 2 mm in all cases: lateral, mean v., 1.21 mm; longitudinal, 1.23 mm; and anteroposterior, 1.18 mm. No serious complications related to the gold marker insertion were noted.
The use of 3 implanted fiducial seeds is an optimal technique for precise set-up in patients with brain tumours treated with external radiotherapy. This commercial system is highly suitable for fractionated stereotactic irradiation. |
---|---|