Accuracy of clinical assessment of infant heart rate in the delivery room

Heart rate (HR) dictates intervention during neonatal resuscitation. Guidelines recommend that HR be assessed by auscultation or palpation. We compared HRs determined clinically with electrocardiography (ECG) in healthy newborns in the delivery room. Clinical assessment by 23 observers randomly allo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Resuscitation 2006-12, Vol.71 (3), p.319-321
Hauptverfasser: Kamlin, C. Omar F., O’Donnell, Colm P.F., Everest, Neil J, Davis, Peter G, Morley, Colin J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Heart rate (HR) dictates intervention during neonatal resuscitation. Guidelines recommend that HR be assessed by auscultation or palpation. We compared HRs determined clinically with electrocardiography (ECG) in healthy newborns in the delivery room. Clinical assessment by 23 observers randomly allocated to assess HR by one of two methods in 26 infants, was found to be inaccurate and underestimate ECG HR. The mean difference between HR assessed by auscultation and palpation ECG and HR using methodology recommended by the Neonatal Resuscitation Programme was 14 and 22 beats per minute respectively.