Inverse scattering for high-resolution interferometric microscopy
We extend the applicability of inverse scattering for optical coherence tomography (OCT) to the case of high numerical aperture focusing optics. We include the effects of tight focusing so that the approach is applicable to any interferometric microscopy method. The applicability to modalities, such...
Gespeichert in:
Veröffentlicht in: | Optics letters 2006-12, Vol.31 (24), p.3585-3587 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We extend the applicability of inverse scattering for optical coherence tomography (OCT) to the case of high numerical aperture focusing optics. We include the effects of tight focusing so that the approach is applicable to any interferometric microscopy method. The applicability to modalities, such as OCT and optical coherence microscopy, enables computed reconstruction of three-dimensional volumes from en face temporal ranging data. Simulations show that the computed structure outside of the focal plane exhibits spatially invariant resolution on par with the resolution achieved at the focal plane. |
---|---|
ISSN: | 0146-9592 1539-4794 |
DOI: | 10.1364/OL.31.003585 |