Use of insulin immunoassays in clinical studies involving rapid-acting insulin analogues: Bi-insulin IRMA preliminary assessment

: In clinical studies involving rapid-acting analogues (RAAs), insulin immunoreactivity is frequently measured, including endogenous, regular insulin (RI) and RAA immunoreactivities. Such a procedure implies equivalent cross-reactivities of all insulins present in serum. Commercially available human...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical chemistry and laboratory medicine 2006-01, Vol.44 (11), p.1379-1382
Hauptverfasser: Agin, Arnaud, Jeandidier, Nathalie, Gasser, Françoise, Grucker, Daniel, Sapin, Rémy
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:: In clinical studies involving rapid-acting analogues (RAAs), insulin immunoreactivity is frequently measured, including endogenous, regular insulin (RI) and RAA immunoreactivities. Such a procedure implies equivalent cross-reactivities of all insulins present in serum. Commercially available human insulin immunoassays have been widely used, but their limitations (including hemolysis and anti-insulin antibodies) were not fully investigated. The aims of our study were to compare cross-reactivities of RI and RAAs in buffer and in serum and to investigate insulin immunoassay pitfalls. : Cross-reactivities were assessed using Bi-insulin IRMA (Schering Cis-Bio International) in phosphate-buffered saline (PBS)-1% bovine serum albumin (BSA) and in pools of sera spiked with RI and RAAs (lispro and aspart). To investigate the influence of hemolysis, a pool of sera spiked with RAA was mixed with a concentrated hemolysate (final hemoglobin concentration 10g/L) and incubated for 3h at room temperature. To determine interference by anti-insulin antibodies, insulin was removed using charcoal from 18 sera with anti-insulin antibodies and from 17 sera without detectable anti-insulin antibodies. These insulin-free samples were then spiked with RI and RAAs and the immunoreactivity was determined. : Compared with buffer, cross-reactivity in serum for RI, lispro and aspart was lower (35%, 29% and 26% lower, respectively). Hemolysis degraded almost all RI and RAAs contained in the serum (≥95%). Anti-insulin antibody interference was significant for RI and RAAs (p≤0.004) and correlated with anti-insulin antibody level in the serum (p≤0.001). : In serum, RI and RAA cross-reactivities are slightly lower than in buffer. For RAA assessment, hemolysed samples should be discarded and anti-insulin antibodies should be removed from samples before immunoreactivity measurements. Clin Chem Lab Med 2006;44:1379–82.
ISSN:1434-6621
1437-4331
DOI:10.1515/CCLM.2006.257