Non‐invasive intrapartum fetal ECG: preliminary report

Objectives  To obtain fetal heart rate, detailed fetal electrocardiography (fECG) signals and uterine contractions during labour using a single device. Design  Prospective observational study. Setting  Delivery suite at a tertiary referral hospital, London, UK. Population  Fifteen patients at median...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:BJOG : an international journal of obstetrics and gynaecology 2005-08, Vol.112 (8), p.1016-1021
Hauptverfasser: Taylor, Myles J.O., Thomas, Matthew J., Smith, Mark J., Oseku‐Afful, Salome, Fisk, Nicholas M., Green, Andrew R., Paterson‐Brown, Sara, Gardiner, Helena M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objectives  To obtain fetal heart rate, detailed fetal electrocardiography (fECG) signals and uterine contractions during labour using a single device. Design  Prospective observational study. Setting  Delivery suite at a tertiary referral hospital, London, UK. Population  Fifteen patients at median gestation of 39 weeks (range 24–41) were recruited at median cervical dilatation of 4.0 cm (range 0–10) of whom 8/15 (53%) had intact amniotic membranes. Methods  Using 12 abdominally sited electrodes, we recorded the composite abdominal signal in pregnancies intrapartum. The recorded data were analysed off‐line using a blind signal separation technique. Main outcome measures  Success of signal separation and fECG time intervals. Results  Successful fECG signal acquisition was achieved in 12/15 (80%) patients and an averaged fECG waveform acquired. In these patients, P and QRS waves were seen in all cases, and T waves in 11/12 (92%). True beat‐to‐beat heart rate (HR) was displayed and measures of its variability obtained. The mother's ECG and uterine electrical activity, shown to match tocographically recorded uterine contractions, were also separated and displayed. Failure to acquire fECG in three cases was attributed to excessive abdominal muscular activity and electrical interference. Conclusions  This study demonstrates a non‐invasive technique that displays detailed intrapartum fECG waveforms, HR variability, maternal ECG and uterine contractions simultaneously, all in a single device and which avoids the potential risks of invasive monitoring with a fetal scalp electrode.
ISSN:1470-0328
1471-0528
DOI:10.1111/j.1471-0528.2005.00643.x