Intra- and inter-rater reliability of the anterior atlantodental interval measurement from conventional lateral view flexion/extension radiographs

An investigation of intra- and inter-rater reliability anterior atlantodental interval (AADI) measurements was conducted using flexion/extension plain radiographs. Flexion and extension lateral radiographs of individuals investigated for atlantoaxial instability were measured for AADI on three occas...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Manual therapy 2005-08, Vol.10 (3), p.219-223
Hauptverfasser: Westaway, Michael D., Hu, William Y., Stratford, Paul W., Maitland, Murray E.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An investigation of intra- and inter-rater reliability anterior atlantodental interval (AADI) measurements was conducted using flexion/extension plain radiographs. Flexion and extension lateral radiographs of individuals investigated for atlantoaxial instability were measured for AADI on three occasions. Intra-rater intraclass correlation coefficients (ICC) were calculated for both flexion (0.99) and extension (0.96). Inter-rater ICCs were 0.93 and 0.84 for flexion and extension, respectively. The AADI measurement proved to be reproducible with a minimal standard of error, between and within raters.
ISSN:1356-689X
1532-2769
DOI:10.1016/j.math.2004.12.001