Comparison of three disposable extraglottic airway devices in spontaneously breathing adults : The LMA-unique™, the soft seal laryngeal mask, and the cobra perilaryngeal airway

The authors compared three disposable extraglottic airway devices in spontaneously breathing anesthetized adults: the LMA-Unique (LMA-U; The Laryngeal Mask Company, San Diego, CA), the Soft Seal laryngeal mask (SS-LM; Portex Ltd., Hythe, United Kingdom), and the Cobra perilaryngeal airway (Cobra-PLA...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Anesthesiology (Philadelphia) 2006-06, Vol.104 (6), p.1165-1169
Hauptverfasser: VAN ZUNDERT, André, AL-SHAIKH, Baha, BRIMACOMBE, Joseph, KOSTER, Jurgen, KONING, Dick, MORTIER, Eric P
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The authors compared three disposable extraglottic airway devices in spontaneously breathing anesthetized adults: the LMA-Unique (LMA-U; The Laryngeal Mask Company, San Diego, CA), the Soft Seal laryngeal mask (SS-LM; Portex Ltd., Hythe, United Kingdom), and the Cobra perilaryngeal airway (Cobra-PLA; Engineered Medical Systems, Inc. Indianapolis, IN). Three hundred twenty consecutive adults (American Society of Anesthesiologists physical status I-III; aged 18-80 yr) were randomly allocated for airway management with one of the three devices. Anesthesia was with fentanyl-propofol for induction and a sevoflurane-nitrous oxide-oxygen-fentanyl mixture for maintenance. Intraoperative data were collected by an unblinded observer about ease of insertion, effective airway time, oropharyngeal leak pressure, anatomical position (determined with a rigid endoscope), intracuff pressure changes, and airway trauma. Data were collected by a blinded observer about sore throat, dysphagia, and dysphonia 2 h after surgery. Insertion was easier with the LMA-U and SS-LM than with the Cobra-PLA (P < 0.02), but the overall failure rates were similar. Effective airway times were similar among groups. Oropharyngeal leak pressure was lower with the LMA-U than with the SS-LM and Cobra-PLA (P < 0.001). Intracuff pressure increased during surgery with all extraglottic airway devices. Anatomical position was better with the Cobra-PLA than with the SS-LMA (P < 0.001) and better with the SS-LM than with LMA-U (P < 0.001). Blood staining was detected more frequently with the Cobra-PLA than with the LMA-U and SS-LM (P < 0.001), but there were no differences in airway morbidity. The LMA-U and SS-LM are easier to insert and cause less trauma than the Cobra-PLA, but the Cobra-PLA has a more effective seal than the LMA-U and better endoscopically determined anatomical position than the LMA-U and SS-LM.
ISSN:0003-3022
1528-1175
DOI:10.1097/00000542-200606000-00010