A G-to-A transition at the fifth position of intron-32 of the dystrophin gene inactivates a splice-donor site both in vivo and in vitro

The splicing pattern of pre-mRNA is unpredictable in genes harboring a single-nucleotide change within the consensus sequence of a splice-donor site. In the dystrophin gene, a transition from G to A at the fifth position of intron-32 (4518 + 5G > A) has been reported as a polymorphism within the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Molecular genetics and metabolism 2005-07, Vol.85 (3), p.213-219
Hauptverfasser: Thi Tran, Hoai Thu, Takeshima, Yasuhiro, Surono, Agus, Yagi, Mariko, Wada, Hiroko, Matsuo, Masafumi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The splicing pattern of pre-mRNA is unpredictable in genes harboring a single-nucleotide change within the consensus sequence of a splice-donor site. In the dystrophin gene, a transition from G to A at the fifth position of intron-32 (4518 + 5G > A) has been reported as a polymorphism within the consensus sequence or a mutation identified in Duchenne muscular dystrophy (DMD). Here, we report both in vivo and in vitro evidence that shows inactivation of the splice-donor site caused by this mutation. In one Japanese DMD case, two novel dystrophin mRNAs were identified in the patient’s lymphocytes, one with a 98 bp deletion of the 3′ end of exon-32 (dys32 − 98) and the other with a 28 bp intron retained between exons 32 and 33 (dys32 + 28). Genomic sequencing disclosed a single-nucleotide change from G to A at the fifth position of intron-32 (4518 + 5G > A). To demonstrate in vitro the inactivation of this splice-donor site by this nucleotide change, mini-dystrophin genes comprising three exons harboring either normal or mutant intron-32 sequences were expressed in HeLa cells, and the splicing products were analyzed by reverse-transcription PCR amplification. A normal transcript consisting of three exons was obtained from the normal construct. From the mutant, we obtained one product containing a 98 bp deletion at the 3′ end of exon-32, indicating complete inactivation of the native splice-donor site. Thus, both in vivo and in vitro experiments demonstrate that 4518 + 5G > A causes a splicing error leading to transcript termination; it did not behave like a silent polymorphism. Our results indicate that the in vitro splicing system is a powerful tool for determining the underlying mechanism of a disease-causing mutation in a splicing consensus sequence.
ISSN:1096-7192
1096-7206
DOI:10.1016/j.ymgme.2005.03.006