Residual blood loss in single use dialyzers: effect of different membranes and flux

The aim of this study was to evaluate the residual blood loss in new type single use dialyzers under the usually prevailing conditions during hemodialysis and to investigate whether or not this loss is dependent on dialyzer membrane composition or flux characteristics. In 158 hemodialysis (HD) patie...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of artificial organs 2006-03, Vol.29 (3), p.286-292
Hauptverfasser: Kalocheretis, P, Vlamis, I, Belesi, C, Makriniotou, I, Zerbala, S, Savidou, E, Zorbas, S, Arvanitis, N, Iatrou, C
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The aim of this study was to evaluate the residual blood loss in new type single use dialyzers under the usually prevailing conditions during hemodialysis and to investigate whether or not this loss is dependent on dialyzer membrane composition or flux characteristics. In 158 hemodialysis (HD) patients, 158 single used dialyzers were studied in corresponding HD sessions. 52/158 dialyzers were made from modified cellulose (acetate, CA or triacetate, CTA) membrane and 106 from synthetic ones (58 with ethyl-vinyl-alcohol (EVAL), 48 with polyacrilonitrile (AN69)). Of those dialyzers 85/158 (58 EVAL+27CA) were low flux (LF) while the other 73 were high flux (HF). Patients underwent 4 hour HD sessions and at the end of the session blood was drawn for the measurement of hematocrit (Ht) and hemoglobin (Hb). Additionally, after the end of dialysis the used dialyzers were rinsed with 1000 mL of 0.05% NH(3) solution in distilled water. The wash was collected and subsequently Hb was measured using the benzidine method. From the volume of the solution and its concentration of Hb, total Hb of the solution was measured and blood loss in terms of red blood cell (RBC) volume was estimated by the use of the formula: RBC (mL) = Total Hb (g) in the solution x patient's Ht (ml/dL) / Patient's Hb (g/dL). For results to be comparable between dialyzers, RBC volume/m(2) of dialyzer membrane was expressed. In 5/158 patients blood loss was also estimated in 6 consecutive HD sessions using the same type of dialyzer. For the sum of the dialyzers, blood loss / dialyzer in terms of RBC volume, expressed as median (range), was 0.978 mL (0.01-23.9). There was statistically significant (p
ISSN:0391-3988
1724-6040
DOI:10.1177/039139880602900306