Comparison of haemodynamic responses to orotracheal intubation with GlideScope® videolaryngoscope and fibreoptic bronchoscope

Summary Background and objective: The GlideScope® videolaryngoscope is a newly developed laryngoscope for tracheal intubation recently introduced into clinical anaesthesia. In this randomised clinical study, we compared the haemodynamic responses to orotracheal intubation using a GlideScope® videola...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of anaesthesiology 2006-06, Vol.23 (6), p.522-526
Hauptverfasser: Xue, F. S., Zhang, G. H., Li, X. Y., Sun, H. T., Li, P., Sun, H. Y., Xu, Y. C., Liu, Y.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Summary Background and objective: The GlideScope® videolaryngoscope is a newly developed laryngoscope for tracheal intubation recently introduced into clinical anaesthesia. In this randomised clinical study, we compared the haemodynamic responses to orotracheal intubation using a GlideScope® videolaryngoscope and a fibreoptic bronchoscope. Methods: Fifty-six adult patients, ASA I–II scheduled for elective plastic surgery under general anaesthesia requiring orotracheal intubation were randomly allocated to either the GlideScope® videolaryngoscope group or the fibreoptic bronchoscope group. After a standard intravenous anaesthetic induction, orotracheal intubation was performed. Noninvasive blood pressure and heart rate were recorded before and after induction, at intubation and for 5 min after intubation at 1 min intervals. Results: As compared with the post-induction values the orotracheal intubations using a fibreoptic bronchoscope and a GlideScope® videolaryngoscope resulted in the significant increases in blood pressures which did not exceed their baseline values. In the two groups, heart rates at intubation and within 2 min after intubation were significantly higher than their baseline values. However, there were no significant differences in blood pressures and heart rates at all time points, their maximal values and maximal percent changes during the observation and the times required to reach their maximal values between the two groups. Conclusions: The orotracheal intubations using a fibreoptic bronchoscope and a GlideScope® videolaryngoscope produce similar haemodynamic responses.
ISSN:0265-0215
1365-2346
DOI:10.1017/S0265021506000299