Endoscopic treatment of thoracic esophageal anastomotic leaks by using silicone-covered, self-expanding polyester stents
Surgery, as well as conservative treatment, in patients with clinically apparent intrathoracic esophageal anastomotic leaks often is associated with poor results and carries a high morbidity and mortality. The successful treatment of esophageal anastomotic insufficiencies and perforations when using...
Gespeichert in:
Veröffentlicht in: | Gastrointestinal endoscopy 2005-06, Vol.61 (7), p.891-896 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Surgery, as well as conservative treatment, in patients with clinically apparent intrathoracic esophageal anastomotic leaks often is associated with poor results and carries a high morbidity and mortality. The successful treatment of esophageal anastomotic insufficiencies and perforations when using covered, self-expanding metallic stents is described.
The feasibility and the outcome of endoscopic treatment of intrathoracic anastomotic leakages when using silicone-covered self-expanding polyester stents were investigated. Twelve consecutive patients presented with clinically apparent intrathoracic esophageal anastomotic leak caused by resection of an epiphrenic diverticulum (n
=
1), esophagectomy for esophageal cancer (n
=
9), or gastrectomy for gastric cancer (n
=
2), were endoscopically treated in our department. The extent of the dehiscences ranged from about 20% to 70% of the anastomotic circumference. After endoscopic lavage and debridement of the leakage at 2-day intervals (mean duration, 8.6 days), a large-diameter polyester stent (Polyflex; proximal/distal diameters 25/21 mm) was placed to seal the leakage. Simultaneously, the periesophageal mediastinum was drained by chest drains.
All 12 patients were successfully treated endoscopically without the need for reoperation. A complete closure of the leakage was obtained in 11 of 12 patients after stent removal (median time to stent retrieval, 4 weeks, range 2-8 weeks). In one patient, a persistent leak was sealed endoscopically after stent removal by using 3 clips. Distal stent migration was obtained in two patients.
The placement of silicone-covered self-expanding polyester stents seems to be a successful minimally invasive treatment option for clinically apparent intrathoracic esophageal anastomotic leaks. |
---|---|