Endoscopic treatment of thoracic esophageal anastomotic leaks by using silicone-covered, self-expanding polyester stents

Surgery, as well as conservative treatment, in patients with clinically apparent intrathoracic esophageal anastomotic leaks often is associated with poor results and carries a high morbidity and mortality. The successful treatment of esophageal anastomotic insufficiencies and perforations when using...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Gastrointestinal endoscopy 2005-06, Vol.61 (7), p.891-896
Hauptverfasser: Schubert, Daniel, Scheidbach, Hubert, Kuhn, Roger, Wex, Cora, Weiss, Guenter, Eder, Frank, Lippert, Hans, Pross, Matthias
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Surgery, as well as conservative treatment, in patients with clinically apparent intrathoracic esophageal anastomotic leaks often is associated with poor results and carries a high morbidity and mortality. The successful treatment of esophageal anastomotic insufficiencies and perforations when using covered, self-expanding metallic stents is described. The feasibility and the outcome of endoscopic treatment of intrathoracic anastomotic leakages when using silicone-covered self-expanding polyester stents were investigated. Twelve consecutive patients presented with clinically apparent intrathoracic esophageal anastomotic leak caused by resection of an epiphrenic diverticulum (n = 1), esophagectomy for esophageal cancer (n = 9), or gastrectomy for gastric cancer (n = 2), were endoscopically treated in our department. The extent of the dehiscences ranged from about 20% to 70% of the anastomotic circumference. After endoscopic lavage and debridement of the leakage at 2-day intervals (mean duration, 8.6 days), a large-diameter polyester stent (Polyflex; proximal/distal diameters 25/21 mm) was placed to seal the leakage. Simultaneously, the periesophageal mediastinum was drained by chest drains. All 12 patients were successfully treated endoscopically without the need for reoperation. A complete closure of the leakage was obtained in 11 of 12 patients after stent removal (median time to stent retrieval, 4 weeks, range 2-8 weeks). In one patient, a persistent leak was sealed endoscopically after stent removal by using 3 clips. Distal stent migration was obtained in two patients. The placement of silicone-covered self-expanding polyester stents seems to be a successful minimally invasive treatment option for clinically apparent intrathoracic esophageal anastomotic leaks.
ISSN:0016-5107
1097-6779
DOI:10.1016/S0016-5107(05)00325-1