Reproducibility of Chronic and Acute Infarct Size Measurement by Delayed Enhancement-Magnetic Resonance Imaging
Reproducibility of Chronic and Acute Infarct Size Measurement by Delayed Enhancement-Magnetic Resonance Imaging Holger Thiele, Mathias J. E. Kappl, Stefan Conradi, Josef Niebauer, Rainer Hambrecht, Gerhard Schuler Infarct size measurement by contrast enhanced magnetic resonance can be used as a surr...
Gespeichert in:
Veröffentlicht in: | Journal of the American College of Cardiology 2006-04, Vol.47 (8), p.1641-1645 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Reproducibility of Chronic and Acute Infarct Size Measurement by Delayed Enhancement-Magnetic Resonance Imaging
Holger Thiele, Mathias J. E. Kappl, Stefan Conradi, Josef Niebauer, Rainer Hambrecht, Gerhard Schuler
Infarct size measurement by contrast enhanced magnetic resonance can be used as a surrogate parameter for acute myocardial infarction treatment trials, if reproducibility is excellent. Patients underwent infarct size measurement on 2 consecutive days for reproducibility assessment. Infarct size difference (bias) between scan I and scan II was −0.5%LV, and limits of agreement were ±2.4%LV, which is better than historical data from other imaging techniques. Magnetic resonance imaging has therefore the potential to serve as a surrogate end point to uncover advantages of new reperfusion strategies.
The aim of this study was to evaluate the reproducibility of acute and chronic infarct size (IS) by delayed enhancement (DE) magnetic resonance imaging (MRI).
Infarct size measurements can be used as surrogate end point to reduce the sample size in studies comparing different reperfusion strategies in myocardial infarction (MI). Delayed enhancement MRI is a rather new technique, and so far infarct IS reproducibility has not been established appropriately.
In 21 patients (10 acute MI and 11 chronic MI), IS was assessed repeatedly on consecutive days by DE-MRI. Reproducibility, interobserver, and intraobserver variabilities were assessed and compared by the Bland-Altman method.
Acute and chronic IS were 17.1 ± 19.6% (range 5.1% to 69.8%) of LV mass (%LV) and 16.9 ± 9.9 %LV (range 2.0% to 36.0%), respectively. Infarct size difference (bias) between scan I and scan II was −0.5 %LV, and limits of agreement were ±2.4 %LV. Mean bias (−0.7 %LV) and limits of agreement (±3.2%) were slightly higher for acute in comparison with chronic MI with −0.4 ± 1.3 %LV. Intraobserver and interobserver variability was low with a mean bias of 0.3 %LV (limits of agreement ± 1.7 %LV) and −0.7 %LV (limits of agreement ± 2.2 %LV), respectively.
Infarct size measurement by DE-MRI is an excellent tool for IS assessment, owing to its excellent repeatability in chronic and acute MI. It has therefore the potential to serve as a surrogate end point to uncover advantages of new reperfusion strategies. |
---|---|
ISSN: | 0735-1097 1558-3597 |
DOI: | 10.1016/j.jacc.2005.11.065 |