Technique for safe removal of an aortic endograft with suprarenal fixation

Complete removal of an aortic endograft with suprarenal fixation is difficult. We report the use of a simple device to extract a Zenith endograft. This device is made by cutting off the tip of the cylinder of a 20-mL syringe and rounding off the edges. The main body of the graft is resheathed by adv...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of vascular surgery 2006-04, Vol.43 (4), p.855-857
Hauptverfasser: Koning, Olivier H.J., Hinnen, Jan-Willem, van Baalen, Jary M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Complete removal of an aortic endograft with suprarenal fixation is difficult. We report the use of a simple device to extract a Zenith endograft. This device is made by cutting off the tip of the cylinder of a 20-mL syringe and rounding off the edges. The main body of the graft is resheathed by advancing the cylinder cranially while keeping the graft in a stable position. This way, the graft collapses and the hooks are withdrawn without tearing the wall of the aorta. The supraceliac clamping time in our patient was less than 2 minutes. This technique offers a safe and fast solution to the potentially hazardous removal of an aortic endograft with suprarenal fixation.
ISSN:0741-5214
1097-6809
DOI:10.1016/j.jvs.2005.12.011