Effects of skin disinfection method, deviation bag, and bacterial screening on clinical safety of platelet transfusions in the Netherlands

BACKGROUND:  Bacterial contamination of blood products is a great hazard for development of fatal transfusion reactions. Bacterial screening of platelet concentrates (PC) by aerobic and anaerobic culturing (BacT/ALERT, bioMérieux) was introduced in the Netherlands in October 2001. STUDY DESIGN AND M...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Transfusion (Philadelphia, Pa.) Pa.), 2006-03, Vol.46 (3), p.476-485
Hauptverfasser: De Korte, Dirk, Curvers, Joyce, De Kort, Wim L.A.M., Hoekstra, Tiny, Van Der Poel, Cees L., Beckers, Erik A.M., Marcelis, Jan H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:BACKGROUND:  Bacterial contamination of blood products is a great hazard for development of fatal transfusion reactions. Bacterial screening of platelet concentrates (PC) by aerobic and anaerobic culturing (BacT/ALERT, bioMérieux) was introduced in the Netherlands in October 2001. STUDY DESIGN AND METHODS:  In November 2002, a nationwide, uniform skin cleansing method was introduced with a double‐swab disinfection with 70 percent isopropyl alcohol. One location routinely used an integrated diversion bag to collect the first 20 to 30 mL. RESULTS:  Over the calendar years 2002 and 2003, in total 113,093 PCs derived from pooled buffy coats were screened. After introduction of the new disinfection method, 0.85 percent were initially positive. This was a small reduction compared to the previous disinfection methods under which 0.95 percent were initially positive. The location with use of the diversion bag showed a significantly lower frequency of bacterial contamination, with 0.50 percent before and 0.37 percent after introduction of 70 percent isopropyl alcohol. In addition 8000 apheresis PCs were also screened, showing 24 initially positive samples (0.30%). CONCLUSION:  The use of the diversion bag and, to a lesser extent, the use of double swabs with 70 percent isopropyl alcohol, led to a reduction of contamination. As expected, predominant contamination with resident skin bacteria was reduced. The combination of diversion bag and new disinfection led to a frequency of initial positive results for pooled five‐donor PCs, which is similar to that of single‐donor apheresis PCs. Furthermore, the bacterial detection system and associated product recall procedures have been shown to be effective in preventing transfusion of contaminated PCs and/or related red cells, especially for rapidly growing bacteria.
ISSN:0041-1132
1537-2995
DOI:10.1111/j.1537-2995.2006.00746.x