Evaluation of Compliance with a Paper-based, Multiplication-factor, Intravenous Insulin Protocol
Background: Hyperglycemia is common in critically ill patients and is an independent risk factor for in-hospital morbidity and mortality. Objective: To assess compliance with a paper-based, multiplication-factor, intravenous insulin protocol. Methods: A retrospective chart review was conducted in a...
Gespeichert in:
Veröffentlicht in: | The Annals of pharmacotherapy 2009-09, Vol.43 (9), p.1413-1418 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background:
Hyperglycemia is common in critically ill patients and is an independent risk factor for in-hospital morbidity and mortality.
Objective:
To assess compliance with a paper-based, multiplication-factor, intravenous insulin protocol.
Methods:
A retrospective chart review was conducted in a 720-bed urban, academic medical center in Boston, Massachusetts. During a 1-month period, compliance with and the consequent safety and efficacy of the Brigham and Women's Hospital paper-based, multiplication-factor, intravenous insulin protocol was evaluated.
Results:
The primary endpoint of protocol compliance, defined as correct adjustment to insulin infusion rate and correct timing of bedside blood glucose concentration (BBGC) checks ±10 minutes of prespecified BBGC check according to the Brigham and Women's Hospital Intravenous Insulin Protocol (BHIP), was 47.2%. Seventy-two patients met inclusion criteria. Appropriate adjustment of infusion rates occurred 68.2% (1206/1768) of the time. Compliance with the timing of BBGC checks was found to be the majority of protocol violations. BBGCs were monitored ±5 minutes of indicated time per the protocol 26.2% (463/1768) of the time. Blood glucose concentration checks within extended timing of ±10 minutes of indicated time per the protocol occurred 793 (44.8%) times. Blood glucose concentration monitoring took place greater than 20 minutes past indicated time 450 (25.5%) times. In 1768 measurements, blood glucose concentrations between 40 and 60 mg/dL occurred 23 (1.3%) times in 12 (16.7%) patients. Blood glucose concentrations 40 mg/dL or less were detected 3 (0.17%) times in 2 (2.7%) patients. None of these hypoglycemic events led to documented complications.
Conclusions:
Overall, a rather low level of compliance with a paper-based, multiplication-factor, intravenous insulin protocol was observed, which warrants further investigation. Compliance rates in this evaluation were found to be similar to the rates observed in previously evaluated fixed-dose intravenous insulin protocols. Protocol noncompliance may be associated with hypo- and hyperglycemia. |
---|---|
ISSN: | 1060-0280 1542-6270 |
DOI: | 10.1345/aph.1M060 |