Short 5Fr vs Long 3Fr Pancreatic Stents in Patients at Risk for Post-Endoscopic Retrograde Cholangiopancreatography Pancreatitis
Background & Aims Prophylactic placement of pancreatic duct (PD) stents reduces the risk of post-endoscopic retrograde cholangiopancreatography pancreatitis (PEP) in high-risk patients. Some endoscopists prefer longer length, unflanged 3Fr PD stents because they are supposedly more effective and...
Gespeichert in:
Veröffentlicht in: | Clinical gastroenterology and hepatology 2009-08, Vol.7 (8), p.834-839 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background & Aims Prophylactic placement of pancreatic duct (PD) stents reduces the risk of post-endoscopic retrograde cholangiopancreatography pancreatitis (PEP) in high-risk patients. Some endoscopists prefer longer length, unflanged 3Fr PD stents because they are supposedly more effective and have a higher rate of spontaneous dislodgement; we compared outcomes of patients with these 2 types of stents. Methods Patients at high risk for PEP were randomly assigned to groups given either a straight, 5Fr, 3 cm long, unflanged PD stent (n = 116) or a 3Fr, 8 cm or longer, unflanged PD stent (n = 133). Abdominal radiographs were obtained at 24 hours, 7 days, and 14 days following stent placement to assess spontaneous stent dislodgement. PEP was defined according to consensus criteria. Results After 14 days, the spontaneous stent dislodgement rates were 98% for 5Fr stents and 88% for 3Fr stents ( P = .0001). PEP occurred in 12% of patients. The incidence of PEP was higher in the 3Fr group (14%) than the 5Fr group (9%), although this difference was not statistically significant ( P = .3). Placement failure did not occur in any patients in the 5Fr stent group, but did occur in 11 of the 133 patients in the 3Fr stent group ( P = .0003). Conclusions Among patients at high-risk for PEP, the spontaneous dislodgement rate of unflanged, short-length, 5Fr PD stents is significantly higher than for unflanged, long-length, 3Fr stents. This decreases the need for endoscopic removal. A higher rate of PD stent placement failure and PEP was observed in patients with 3Fr stents. To view this article's video abstract, go to the AGA's YouTube Channel. |
---|---|
ISSN: | 1542-3565 1542-7714 |