Analysis of acetylene in blood and urine using cryogenic gas chromatography–mass spectrometry

A method for quantitative analysis of acetylene in blood and urine samples was investigated. Using cryogenic gas chromatography–mass spectrometry (GC–MS), acetylene was measured with isobutane as the internal standard in the headspace method, which revealed a linear response over the entire composit...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of chromatography. B 2009-09, Vol.877 (25), p.2658-2661
Hauptverfasser: Kashiwagi, Masayuki, Hara, Kenji, Fujii, Hiroshi, Kageura, Mitsuyoshi, Takamoto, Mutsuo, Matsusue, Aya, Sugimura, Tomoko, Kubo, Shin-ichi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A method for quantitative analysis of acetylene in blood and urine samples was investigated. Using cryogenic gas chromatography–mass spectrometry (GC–MS), acetylene was measured with isobutane as the internal standard in the headspace method, which revealed a linear response over the entire composite range with an excellent correlation coefficient, both in blood ( R = 0.9968, range = 5.39–43.1 μg/ml) and urine ( R = 0.9972, range = 2.16–10.8 μg/ml). The coefficients of variation (CV) for blood ranged from 2.62 to 11.6% for intra-day and 4.55 to 10.4% for inter-day. The CV for urine ranged from 2.38 to 3.10% for intra-day and 4.83 to 11.0% for inter-day. The recovery rate as an index of accuracy ranged from 83 to 111%. The present method showed good reliability, and is also simple and rapid. In actual samples from a charred cadaver due to acetylene explosion, the measured concentrations of acetylene by this method were 21.5 μg/ml for femoral vein blood, 17.9 μg/ml for right atrial blood, 25.5 μg/ml for left atrial blood and 7.49 μg/ml for urine. Quantification of acetylene provides important information, because the acetylene concentration is a vital reaction or sign. For example, when acetylene is filled in a closed space and then explodes, in antemortem explosion, the blood acetylene concentration of the cadaver might be significant. On the other hand, in postmortem explosion, acetylene is not detected in blood. Furthermore, when several victims are involved in one explosion, comparison of the sample concentrations can also provide useful information to establish the conditions at the accident scene; therefore, the present method is useful in forensics.
ISSN:1570-0232
1873-376X
DOI:10.1016/j.jchromb.2009.04.022