In-Vivo Imaging of Changes in Abdominal Aortic Aneurysm Thrombus Volume during the Cardiac Cycle

Purpose: To evaluate in-vivo thrombus compressibility in abdominal aortic aneurysms (AAAs) to hopefully shed light on the biomechanical importance of intraluminal thrombus. Methods: Dynamic electrocardiographically-gated computed tomographic angiography was performed in 17 AAA patients (15 men; mean...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of endovascular therapy 2009-06, Vol.16 (3), p.314-319
Hauptverfasser: Truijers, Maarten, Fillinger, Mark F., Renema, KlaasJan W., Marra, Steven P., Oostveen, Luuk J., Kurvers, Harrie A.J.M., SchultzeKool, Leo J., Blankensteijn, Jan D.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose: To evaluate in-vivo thrombus compressibility in abdominal aortic aneurysms (AAAs) to hopefully shed light on the biomechanical importance of intraluminal thrombus. Methods: Dynamic electrocardiographically-gated computed tomographic angiography was performed in 17 AAA patients (15 men; mean age 73 years, range 69–76): 11 scheduled for surgical repair and 6 under routine surveillance. The volumes of intraluminal thrombus, the lumen, and the total aneurysm were quantified for each phase of the cardiac cycle. Thrombus compressibility was defined as the percent change in thrombus volume between diastole and peak systole. Continuous data are presented as medians and interquartile ranges (IQR). Results: A substantial interpatient variability was observed in thrombus compressibility, ranging from 0.4% to 43.6% (0.2 to 13.5 mL, respectively). Both thrombus and lumen volumes varied substantially during the cardiac cycle. As lumen volume increased (5.2%, IQR 2.8%–8.8%), thrombus volume decreased (3.0%, IQR 1.0%–4.6%). Total aneurysm volume remained relatively constant (1.3%, IQR 0.4–1.9%). Changes in lumen volume were inversely correlated with changes in thrombus volume (r=–0.73; p=0.001). Conclusion: In-vivo thrombus compressibility varied from patient to patient, and this variation was irrespective of aneurysm size, pulse pressure, and thrombus volume. This suggests that thrombus might act as a biomechanical buffer in some, while it has virtually no effect in others. Whether differences in thrombus compressibility alter the risk of rupture will be the focus of future research.
ISSN:1526-6028
1545-1550
DOI:10.1583/08-2625.1