Ultrasound imaging to evaluate Creatsas vaginoplasty
Objective: To present a new imaging technique for the evaluation of the functional effectiveness of Creatsas vaginoplasty. Method: Eighteen women with Mayer–Rokitansky–Küster–Hauser syndrome underwent a transabdominal and transperineal ultrasound examination 4 weeks and 6 months after the surgical c...
Gespeichert in:
Veröffentlicht in: | International journal of gynecology and obstetrics 2005-04, Vol.89 (1), p.31-34 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objective: To present a new imaging technique for the evaluation of the functional effectiveness of Creatsas vaginoplasty.
Method: Eighteen women with Mayer–Rokitansky–Küster–Hauser syndrome underwent a transabdominal and transperineal ultrasound examination 4 weeks and 6 months after the surgical creation of a neovagina, and then yearly, with a condom filled with water as a distending and imaging medium. The functional length and width of the neovagina and its axis deviation were assessed, as well as the postoperative quality of the women's sexual life.
Results: A functional vagina 10 to 12 cm in length and 4 to 5 cm in width was observed; its axis deviation, which was similar to the anatomic deviation, was easily determined; and 94.5% of the women reported a satisfactory while 5.5% reported an adequate sexual life.
Conclusion: This new imaging technique is a simple and effective alternative for the evaluation of the postoperative effectiveness of colpopoiesis. |
---|---|