Comparative in vitro study on a ultra-high roughness and dense titanium coating
A new implant surface has been developed with the purpose of avoiding as much stress shielding as possible, and thus prolong the prosthesis lifespan. The aim of this study was to investigate the in vitro effect of this new ultra-high roughness and dense Titanium (Ti) surface (PG60, R a = 74 μ m ) in...
Gespeichert in:
Veröffentlicht in: | Biomaterials 2005-08, Vol.26 (24), p.4948-4955 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 4955 |
---|---|
container_issue | 24 |
container_start_page | 4948 |
container_title | Biomaterials |
container_volume | 26 |
creator | Borsari, Veronica Giavaresi, Gianluca Fini, Milena Torricelli, Paola Tschon, Matilde Chiesa, Roberto Chiusoli, Loris Salito, Armando Volpert, Andreas Giardino, Roberto |
description | A new implant surface has been developed with the purpose of avoiding as much stress shielding as possible, and thus prolong the prosthesis lifespan. The aim of this study was to investigate the in vitro effect of this new ultra-high roughness and dense Titanium (Ti) surface (PG60,
R
a
=
74
μ
m
) in comparison with medium (TI01,
R
a
=
18
μ
m
) and high (TI60,
R
a
=
40
μ
m
) roughness and open porous coatings; all the coatings were obtained by vacuum plasma spraying. MG63 osteoblast-like cells were seeded on the tested materials and polystyrene, as control, for 3 and 7 days. Cells proliferated on the material surfaces similarly to the control. Alkaline phosphatase activity had lower values for TI60 than TI01 (
p |
doi_str_mv | 10.1016/j.biomaterials.2005.01.010 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_67527050</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0142961205000359</els_id><sourcerecordid>67527050</sourcerecordid><originalsourceid>FETCH-LOGICAL-c471t-d4afccc690ef3df045a6e20d6228807116c9a0db2f3b3f8a49cff172e40e07303</originalsourceid><addsrcrecordid>eNqNkdGLEzEQxoN4ePX0X5Dgg29bJ9kku_FNqqfCwb2czyFNZtuU7qYm2cL996a04L1VGBgGfjPfx3yEfGSwZMDU591yHeJoC6Zg93nJAeQSWC14RRas7_pGapCvyQKY4I1WjN-StznvoM4g-Btyy2SntGxhQR5XcTzYZEs4Ig0TPYaSIs1l9s80TtTSeV-SbbZhs6UpzpvthDlTO3nqccpISyh2CvNIXaw3ps07cjNUU_j-0u_I7_vvT6ufzcPjj1-rrw-NEx0rjRd2cM4pDTi0fgAhrUIOXnHe99Axppy24Nd8aNft0Fuh3TCwjqMAhK6F9o58Ot89pPhnxlzMGLLD_d5OGOdsVCd5B_I6yLWEXrD2OtiLnrXiOsiqtFa6r-CXM-hSzDnhYA4pjDY9GwbmlKTZmZdJmlOSBlitk-8PF5V5PaL_t3qJrgLfzgDWNx8DJpNdwMmhDwldMT6G_9H5C8E0tkY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>17529698</pqid></control><display><type>article</type><title>Comparative in vitro study on a ultra-high roughness and dense titanium coating</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Borsari, Veronica ; Giavaresi, Gianluca ; Fini, Milena ; Torricelli, Paola ; Tschon, Matilde ; Chiesa, Roberto ; Chiusoli, Loris ; Salito, Armando ; Volpert, Andreas ; Giardino, Roberto</creator><creatorcontrib>Borsari, Veronica ; Giavaresi, Gianluca ; Fini, Milena ; Torricelli, Paola ; Tschon, Matilde ; Chiesa, Roberto ; Chiusoli, Loris ; Salito, Armando ; Volpert, Andreas ; Giardino, Roberto</creatorcontrib><description><![CDATA[A new implant surface has been developed with the purpose of avoiding as much stress shielding as possible, and thus prolong the prosthesis lifespan. The aim of this study was to investigate the in vitro effect of this new ultra-high roughness and dense Titanium (Ti) surface (PG60,
R
a
=
74
μ
m
) in comparison with medium (TI01,
R
a
=
18
μ
m
) and high (TI60,
R
a
=
40
μ
m
) roughness and open porous coatings; all the coatings were obtained by vacuum plasma spraying. MG63 osteoblast-like cells were seeded on the tested materials and polystyrene, as control, for 3 and 7 days. Cells proliferated on the material surfaces similarly to the control. Alkaline phosphatase activity had lower values for TI60 than TI01 (
p<0.0005) and PG60 (
p<0.005). Osteocalcin levels measured on TI60 were significantly (
p<0.0005) lower in comparison with TI01 and PG60 at 7 days. Procollagen-I synthesis reduced with increasing roughness and the lowest data was found for PG60. While at 3 days Transforming Growth Factor
β1 levels augmented with increasing roughness, at 7 days TI60, the high roughness surface, was significantly lower than PG60 (
p<0.005) and TI01 (
p<0.001). All tested materials showed significantly higher Interleukin-6 levels than those of polystyrene at both experimental times. Nitric Oxide activity on TI01 was significantly (
p<0.05) higher than on TI60 and polystyrene.
In conclusion, the new ultra-high roughness and dense coating PG60 provided a good biological response, even though, at least in vitro, it behaved similarly to the coatings already used in orthopaedics.]]></description><identifier>ISSN: 0142-9612</identifier><identifier>EISSN: 1878-5905</identifier><identifier>DOI: 10.1016/j.biomaterials.2005.01.010</identifier><identifier>PMID: 15769530</identifier><language>eng</language><publisher>Netherlands: Elsevier Ltd</publisher><subject>Cell Differentiation ; Cell Line ; Cell Proliferation ; Cell Survival ; Coated Materials, Biocompatible - chemistry ; Cytokines ; Hardness ; Humans ; Materials Testing ; Osseointegration - physiology ; Osteoblast ; Osteoblasts - cytology ; Osteoblasts - physiology ; Plasma spraying ; Surface Properties ; Surface roughness ; Titanium ; Titanium - analysis ; Titanium - chemistry</subject><ispartof>Biomaterials, 2005-08, Vol.26 (24), p.4948-4955</ispartof><rights>2005 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c471t-d4afccc690ef3df045a6e20d6228807116c9a0db2f3b3f8a49cff172e40e07303</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0142961205000359$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15769530$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Borsari, Veronica</creatorcontrib><creatorcontrib>Giavaresi, Gianluca</creatorcontrib><creatorcontrib>Fini, Milena</creatorcontrib><creatorcontrib>Torricelli, Paola</creatorcontrib><creatorcontrib>Tschon, Matilde</creatorcontrib><creatorcontrib>Chiesa, Roberto</creatorcontrib><creatorcontrib>Chiusoli, Loris</creatorcontrib><creatorcontrib>Salito, Armando</creatorcontrib><creatorcontrib>Volpert, Andreas</creatorcontrib><creatorcontrib>Giardino, Roberto</creatorcontrib><title>Comparative in vitro study on a ultra-high roughness and dense titanium coating</title><title>Biomaterials</title><addtitle>Biomaterials</addtitle><description><![CDATA[A new implant surface has been developed with the purpose of avoiding as much stress shielding as possible, and thus prolong the prosthesis lifespan. The aim of this study was to investigate the in vitro effect of this new ultra-high roughness and dense Titanium (Ti) surface (PG60,
R
a
=
74
μ
m
) in comparison with medium (TI01,
R
a
=
18
μ
m
) and high (TI60,
R
a
=
40
μ
m
) roughness and open porous coatings; all the coatings were obtained by vacuum plasma spraying. MG63 osteoblast-like cells were seeded on the tested materials and polystyrene, as control, for 3 and 7 days. Cells proliferated on the material surfaces similarly to the control. Alkaline phosphatase activity had lower values for TI60 than TI01 (
p<0.0005) and PG60 (
p<0.005). Osteocalcin levels measured on TI60 were significantly (
p<0.0005) lower in comparison with TI01 and PG60 at 7 days. Procollagen-I synthesis reduced with increasing roughness and the lowest data was found for PG60. While at 3 days Transforming Growth Factor
β1 levels augmented with increasing roughness, at 7 days TI60, the high roughness surface, was significantly lower than PG60 (
p<0.005) and TI01 (
p<0.001). All tested materials showed significantly higher Interleukin-6 levels than those of polystyrene at both experimental times. Nitric Oxide activity on TI01 was significantly (
p<0.05) higher than on TI60 and polystyrene.
In conclusion, the new ultra-high roughness and dense coating PG60 provided a good biological response, even though, at least in vitro, it behaved similarly to the coatings already used in orthopaedics.]]></description><subject>Cell Differentiation</subject><subject>Cell Line</subject><subject>Cell Proliferation</subject><subject>Cell Survival</subject><subject>Coated Materials, Biocompatible - chemistry</subject><subject>Cytokines</subject><subject>Hardness</subject><subject>Humans</subject><subject>Materials Testing</subject><subject>Osseointegration - physiology</subject><subject>Osteoblast</subject><subject>Osteoblasts - cytology</subject><subject>Osteoblasts - physiology</subject><subject>Plasma spraying</subject><subject>Surface Properties</subject><subject>Surface roughness</subject><subject>Titanium</subject><subject>Titanium - analysis</subject><subject>Titanium - chemistry</subject><issn>0142-9612</issn><issn>1878-5905</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqNkdGLEzEQxoN4ePX0X5Dgg29bJ9kku_FNqqfCwb2czyFNZtuU7qYm2cL996a04L1VGBgGfjPfx3yEfGSwZMDU591yHeJoC6Zg93nJAeQSWC14RRas7_pGapCvyQKY4I1WjN-StznvoM4g-Btyy2SntGxhQR5XcTzYZEs4Ig0TPYaSIs1l9s80TtTSeV-SbbZhs6UpzpvthDlTO3nqccpISyh2CvNIXaw3ps07cjNUU_j-0u_I7_vvT6ufzcPjj1-rrw-NEx0rjRd2cM4pDTi0fgAhrUIOXnHe99Axppy24Nd8aNft0Fuh3TCwjqMAhK6F9o58Ot89pPhnxlzMGLLD_d5OGOdsVCd5B_I6yLWEXrD2OtiLnrXiOsiqtFa6r-CXM-hSzDnhYA4pjDY9GwbmlKTZmZdJmlOSBlitk-8PF5V5PaL_t3qJrgLfzgDWNx8DJpNdwMmhDwldMT6G_9H5C8E0tkY</recordid><startdate>20050801</startdate><enddate>20050801</enddate><creator>Borsari, Veronica</creator><creator>Giavaresi, Gianluca</creator><creator>Fini, Milena</creator><creator>Torricelli, Paola</creator><creator>Tschon, Matilde</creator><creator>Chiesa, Roberto</creator><creator>Chiusoli, Loris</creator><creator>Salito, Armando</creator><creator>Volpert, Andreas</creator><creator>Giardino, Roberto</creator><general>Elsevier Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope><scope>F28</scope><scope>7SR</scope><scope>7TB</scope><scope>7U5</scope><scope>8BQ</scope><scope>JG9</scope><scope>L7M</scope><scope>7X8</scope></search><sort><creationdate>20050801</creationdate><title>Comparative in vitro study on a ultra-high roughness and dense titanium coating</title><author>Borsari, Veronica ; Giavaresi, Gianluca ; Fini, Milena ; Torricelli, Paola ; Tschon, Matilde ; Chiesa, Roberto ; Chiusoli, Loris ; Salito, Armando ; Volpert, Andreas ; Giardino, Roberto</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c471t-d4afccc690ef3df045a6e20d6228807116c9a0db2f3b3f8a49cff172e40e07303</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Cell Differentiation</topic><topic>Cell Line</topic><topic>Cell Proliferation</topic><topic>Cell Survival</topic><topic>Coated Materials, Biocompatible - chemistry</topic><topic>Cytokines</topic><topic>Hardness</topic><topic>Humans</topic><topic>Materials Testing</topic><topic>Osseointegration - physiology</topic><topic>Osteoblast</topic><topic>Osteoblasts - cytology</topic><topic>Osteoblasts - physiology</topic><topic>Plasma spraying</topic><topic>Surface Properties</topic><topic>Surface roughness</topic><topic>Titanium</topic><topic>Titanium - analysis</topic><topic>Titanium - chemistry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Borsari, Veronica</creatorcontrib><creatorcontrib>Giavaresi, Gianluca</creatorcontrib><creatorcontrib>Fini, Milena</creatorcontrib><creatorcontrib>Torricelli, Paola</creatorcontrib><creatorcontrib>Tschon, Matilde</creatorcontrib><creatorcontrib>Chiesa, Roberto</creatorcontrib><creatorcontrib>Chiusoli, Loris</creatorcontrib><creatorcontrib>Salito, Armando</creatorcontrib><creatorcontrib>Volpert, Andreas</creatorcontrib><creatorcontrib>Giardino, Roberto</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineered Materials Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Biomaterials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Borsari, Veronica</au><au>Giavaresi, Gianluca</au><au>Fini, Milena</au><au>Torricelli, Paola</au><au>Tschon, Matilde</au><au>Chiesa, Roberto</au><au>Chiusoli, Loris</au><au>Salito, Armando</au><au>Volpert, Andreas</au><au>Giardino, Roberto</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparative in vitro study on a ultra-high roughness and dense titanium coating</atitle><jtitle>Biomaterials</jtitle><addtitle>Biomaterials</addtitle><date>2005-08-01</date><risdate>2005</risdate><volume>26</volume><issue>24</issue><spage>4948</spage><epage>4955</epage><pages>4948-4955</pages><issn>0142-9612</issn><eissn>1878-5905</eissn><abstract><![CDATA[A new implant surface has been developed with the purpose of avoiding as much stress shielding as possible, and thus prolong the prosthesis lifespan. The aim of this study was to investigate the in vitro effect of this new ultra-high roughness and dense Titanium (Ti) surface (PG60,
R
a
=
74
μ
m
) in comparison with medium (TI01,
R
a
=
18
μ
m
) and high (TI60,
R
a
=
40
μ
m
) roughness and open porous coatings; all the coatings were obtained by vacuum plasma spraying. MG63 osteoblast-like cells were seeded on the tested materials and polystyrene, as control, for 3 and 7 days. Cells proliferated on the material surfaces similarly to the control. Alkaline phosphatase activity had lower values for TI60 than TI01 (
p<0.0005) and PG60 (
p<0.005). Osteocalcin levels measured on TI60 were significantly (
p<0.0005) lower in comparison with TI01 and PG60 at 7 days. Procollagen-I synthesis reduced with increasing roughness and the lowest data was found for PG60. While at 3 days Transforming Growth Factor
β1 levels augmented with increasing roughness, at 7 days TI60, the high roughness surface, was significantly lower than PG60 (
p<0.005) and TI01 (
p<0.001). All tested materials showed significantly higher Interleukin-6 levels than those of polystyrene at both experimental times. Nitric Oxide activity on TI01 was significantly (
p<0.05) higher than on TI60 and polystyrene.
In conclusion, the new ultra-high roughness and dense coating PG60 provided a good biological response, even though, at least in vitro, it behaved similarly to the coatings already used in orthopaedics.]]></abstract><cop>Netherlands</cop><pub>Elsevier Ltd</pub><pmid>15769530</pmid><doi>10.1016/j.biomaterials.2005.01.010</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0142-9612 |
ispartof | Biomaterials, 2005-08, Vol.26 (24), p.4948-4955 |
issn | 0142-9612 1878-5905 |
language | eng |
recordid | cdi_proquest_miscellaneous_67527050 |
source | MEDLINE; Elsevier ScienceDirect Journals |
subjects | Cell Differentiation Cell Line Cell Proliferation Cell Survival Coated Materials, Biocompatible - chemistry Cytokines Hardness Humans Materials Testing Osseointegration - physiology Osteoblast Osteoblasts - cytology Osteoblasts - physiology Plasma spraying Surface Properties Surface roughness Titanium Titanium - analysis Titanium - chemistry |
title | Comparative in vitro study on a ultra-high roughness and dense titanium coating |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T11%3A32%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparative%20in%20vitro%20study%20on%20a%20ultra-high%20roughness%20and%20dense%20titanium%20coating&rft.jtitle=Biomaterials&rft.au=Borsari,%20Veronica&rft.date=2005-08-01&rft.volume=26&rft.issue=24&rft.spage=4948&rft.epage=4955&rft.pages=4948-4955&rft.issn=0142-9612&rft.eissn=1878-5905&rft_id=info:doi/10.1016/j.biomaterials.2005.01.010&rft_dat=%3Cproquest_cross%3E67527050%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=17529698&rft_id=info:pmid/15769530&rft_els_id=S0142961205000359&rfr_iscdi=true |