Assessment of Ascorbic Acid Stability in Different Multilayered Parenteral Nutrition Bags: Critical Influence of the Bag Wall Material
Background: The recent development of multilayered bags has minimized ascorbic acid oxidation in parenteral nutrition (PN) admixtures. However, the gas-barrier property of multilayered bags depends on their plastic material. This study compared ascorbic acid stability in different multilayered bags...
Gespeichert in:
Veröffentlicht in: | JPEN. Journal of parenteral and enteral nutrition 2005-03, Vol.29 (2), p.125-130 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background: The recent development of multilayered bags has
minimized ascorbic acid oxidation in parenteral nutrition (PN) admixtures.
However, the gas-barrier property of multilayered bags depends on their
plastic material. This study compared ascorbic acid stability in different
multilayered bags under experimental conditions. Methods: Oxygen
permeability of a newly developed 6-layered bag (6-L) was compared with a
highly mechanical-resistant 3-layered bag (3-LR) and a highly
flexible 3-layered bag (3-LF) using gas chromatography. Ascorbic
acid stability was assessed by iodine titration in bags filled with 2.5 L
H2O and 40 g carbohydrates after setting residual O2
content at ≤1 or ≥5 ppm. The effect of storage at 4°C, 21°C, and
40°C on ascorbic acid stability was assessed over 48 hours in a complete
PN admixture (ie, 330 g carbohydrates, 100 g lipids, 96 g amino acids and
trace elements) using high-pressure liquid chromatography. Results:
Oxygen permeability was markedly reduced in 6-L bags (0.5 mL O2
/m2/d) compared with 3-LR (150 mL O2
/m2/d) and 3-LR (1500 mL O2/m2/d).
Accordingly, ascorbic acid was more stable in 6-L bags (half-life
[T1/2] = 16 days up to 40°C) than in 3-LR
(T1/2 = 9 days at 4°C, 47 hours at 21°C and 29 hours at
40°C) and 3-LF (T1/2 = 15 hours at 4°C, 10 hours
at 21°C, and 6 hours at 40°C). During the first 6 hours after PN
admixture compounding, an additive ascorbic acid loss of 4.6 ± 0.5
mg/L/ppm O2 occurred because of residual O2 in the bag.
Conclusions: The new combination of plastic layers and careful
O2 monitoring during the filling process allowed near to complete
prevention of ascorbic acid degradation in multilayered PN bags during 48
hours, regardless of the storage temperature.
Comparisons between different multilayered parenteral nutrition bags showed that the gas permeability of the bag wall material is the main limiting factor for ascorbic acid stability. Near to complete prevention of ascorbic acid oxidation in the parenteral nutrition bags was only possible in a newly developed 6-layered bag. |
---|---|
ISSN: | 0148-6071 1941-2444 |
DOI: | 10.1177/0148607105029002125 |