Venous Coupler for Free-flap Anastomosis

Free-flap surgery has become a routine procedure in breast reconstruction. The microvascular surgical anastomosis remains one of the technically sensitive aspects of free-tissue transfers. Between December 2006 and September 2007, 12 anastomoses were performed with a venous coupling device from Syno...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Anticancer research 2009-07, Vol.29 (7), p.2827-2830
Hauptverfasser: CAMARA, O, HERRMANN, J, EGBE, A, KOCH, I, GAJDA, M, RUNNEBAUM, Lb
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Free-flap surgery has become a routine procedure in breast reconstruction. The microvascular surgical anastomosis remains one of the technically sensitive aspects of free-tissue transfers. Between December 2006 and September 2007, 12 anastomoses were performed with a venous coupling device from Synovis. There were no free-flap failures. Venous congestion occurred in only one case and was managed successfully with leeches. No major complications were observed. The Synovis venous coupling device system allowed a time-efficient and safe venous anastomosis in breast reconstruction.
ISSN:0250-7005
1791-7530