Why is flow-mediated dilation dependent on arterial size? Assessment of the shear stimulus using phase-contrast magnetic resonance imaging

1 Division of Cardiology, 2 Department of Radiology, Johns Hopkins University School of Medicine, Baltimore; and 3 Applied Sciences Laboratory, General Electric Medical Systems, Baltimore, Maryland Submitted 21 June 2004 ; accepted in final form 30 August 2004 Flow-mediated dilation (FMD) is strongl...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of physiology. Heart and circulatory physiology 2005-02, Vol.288 (2), p.H822-H828
Hauptverfasser: Silber, Harry A, Ouyang, Pamela, Bluemke, David A, Gupta, Sandeep N, Foo, Thomas K, Lima, Joao A. C
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:1 Division of Cardiology, 2 Department of Radiology, Johns Hopkins University School of Medicine, Baltimore; and 3 Applied Sciences Laboratory, General Electric Medical Systems, Baltimore, Maryland Submitted 21 June 2004 ; accepted in final form 30 August 2004 Flow-mediated dilation (FMD) is strongly dependent on arterial size, but the reasons for this phenomenon are poorly understood. We have previously shown that FMD is greater in small brachial arteries because the shear stress stimulus is greater in small brachial arteries. However, it is unclear why the shear stimulus is greater in small arteries. Furthermore, this relationship has not been investigated in other, differently sized arterial beds. Postischemic systolic shear stress and resulting FMD were evaluated in the brachial and femoral arteries of 24 young, healthy adults using phase-contrast magnetic resonance imaging. Arterial shear and radius were calculated from the velocity profile via a best-fit parabola before and after occlusion. Summing the velocity pixels provided hyperemic systolic flow. FMD was proportional to hyperemic shear in the brachial and femoral arteries ( P < 0.0001, r = 0.60). Hyperemic systolic flow was proportional to radius 2 ( P < 0.0001, r = 0.93). Applying this relationship to the Poiseuille equation (shear is proportional to flow/radius 3 ) shows that hyperemic shear is proportional to radius 2 /radius 3 and, therefore, explains why hyperemic shear is proportional to 1/radius. We conclude that FMD is proportional to hyperemic systolic shear stress in both the brachial and the femoral arteries. The hyperemic shear stimulus for FMD is greater in small arteries due to the dependence of postischemic systolic flow on radius squared. Therefore, greater FMD in small arteries does not necessarily reflect better conduit artery endothelial function. Evaluating the shear stimulus using phase-contrast magnetic resonance imaging enhances the understanding of mechanisms underlying FMD. endothelial function; vasodilation; blood flow Address for reprint requests and other correspondence: H. A. Silber, Cardiology A-1 East, Johns Hopkins Bayview Medical Center, 4940 Eastern Ave., Baltimore, MD 21224 (E-mail: hsilber{at}jhmi.edu )
ISSN:0363-6135
1522-1539
DOI:10.1152/ajpheart.00612.2004